CSA Group Cardiovascular implants and artificial organs - Blood-gas exchangers (oxygenators) ISO 7199:2016

Description
ISO 7199:2016 specifies requirements for sterile, single-use, extracorporeal blood-gas exchangers (oxygenators) intended for supply of oxygen to, and removal of carbon dioxide from, the blood of humans. ISO 7199:2016 also applies to heat exchangers and arterial filters that are integral parts of the oxygenator. ISO 7199:2016 also applies to external equipment unique to the use of the oxygenator. ISO 7199:2016 does not apply to - implanted oxygenators, - liquid oxygenators, - extracorporeal circuits (blood tubing), - separate heat exchangers, - separate ancillary devices, and - separate arterial line filter.
Description
ISO 7199:2016 specifies requirements for sterile, single-use, extracorporeal blood-gas exchangers (oxygenators) intended for supply of oxygen to, and removal of carbon dioxide from, the blood of humans. ISO 7199:2016 also applies to heat exchangers and arterial filters that are integral parts of the oxygenator. ISO 7199:2016 also applies to external equipment unique to the use of the oxygenator. ISO 7199:2016 does not apply to - implanted oxygenators, - liquid oxygenators, - extracorporeal circuits (blood tubing), - separate heat exchangers, - separate ancillary devices, and - separate arterial line filter.

Suppliers

Company
Product
Description
Supplier Links
Cardiovascular implants and artificial organs - Blood-gas exchangers (oxygenators) - ISO 7199:2016 - CSA Group
Toronto, Ontario, Canada
Cardiovascular implants and artificial organs - Blood-gas exchangers (oxygenators)
ISO 7199:2016
Cardiovascular implants and artificial organs - Blood-gas exchangers (oxygenators) ISO 7199:2016
ISO 7199:2016 specifies requirements for sterile, single-use, extracorporeal blood-gas exchangers (oxygenators) intended for supply of oxygen to, and removal of carbon dioxide from, the blood of humans. ISO 7199:2016 also applies to heat exchangers and arterial filters that are integral parts of the oxygenator. ISO 7199:2016 also applies to external equipment unique to the use of the oxygenator. ISO 7199:2016 does not apply to - implanted oxygenators, - liquid oxygenators, - extracorporeal circuits (blood tubing), - separate heat exchangers, - separate ancillary devices, and - separate arterial line filter.

ISO 7199:2016 specifies requirements for sterile, single-use, extracorporeal blood-gas exchangers (oxygenators) intended for supply of oxygen to, and removal of carbon dioxide from, the blood of humans.

ISO 7199:2016 also applies to heat exchangers and arterial filters that are integral parts of the oxygenator.

ISO 7199:2016 also applies to external equipment unique to the use of the oxygenator.

ISO 7199:2016 does not apply to

- implanted oxygenators,

- liquid oxygenators,

- extracorporeal circuits (blood tubing),

- separate heat exchangers,

- separate ancillary devices, and

- separate arterial line filter.