CSA Group Polyglycols for industrial use - Determination of hydroxyl number - Phthalic anhydride esterification method ISO 6796:1981

Description
The hydroxy groups present in a test portion are esterified with phthalic anhydride. The excess phthalic anhydrids is hydrolyzed and the phthalic acid formed is neutralized with standard volumetric sodium hydroxide solution. If the sample contains free acidity or alkalinity a corresponding correction is made. From the corrected hydroxyl number, the apparat relative molecular mass may be calculated by a formula given.
Description
The hydroxy groups present in a test portion are esterified with phthalic anhydride. The excess phthalic anhydrids is hydrolyzed and the phthalic acid formed is neutralized with standard volumetric sodium hydroxide solution. If the sample contains free acidity or alkalinity a corresponding correction is made. From the corrected hydroxyl number, the apparat relative molecular mass may be calculated by a formula given.

Suppliers

Company
Product
Description
Supplier Links
Polyglycols for industrial use - Determination of hydroxyl number - Phthalic anhydride esterification method - ISO 6796:1981 - CSA Group
Toronto, Ontario, Canada
Polyglycols for industrial use - Determination of hydroxyl number - Phthalic anhydride esterification method
ISO 6796:1981
Polyglycols for industrial use - Determination of hydroxyl number - Phthalic anhydride esterification method ISO 6796:1981
The hydroxy groups present in a test portion are esterified with phthalic anhydride. The excess phthalic anhydrids is hydrolyzed and the phthalic acid formed is neutralized with standard volumetric sodium hydroxide solution. If the sample contains free acidity or alkalinity a corresponding correction is made. From the corrected hydroxyl number, the apparat relative molecular mass may be calculated by a formula given.

The hydroxy groups present in a test portion are esterified with phthalic anhydride. The excess phthalic anhydrids is hydrolyzed and the phthalic acid formed is neutralized with standard volumetric sodium hydroxide solution. If the sample contains free acidity or alkalinity a corresponding correction is made. From the corrected hydroxyl number, the apparat relative molecular mass may be calculated by a formula given.

Supplier's Site

Technical Specifications

  CSA Group
Product Category Standards and Technical Documents
Product Number ISO 6796:1981
Product Name Polyglycols for industrial use - Determination of hydroxyl number - Phthalic anhydride esterification method