CSA Group Hydrometry - Measurement of discharge by the ultrasonic transit time (time of flight) method ISO 6416:2017

Description
ISO 6416 describes the establishment and operation of an ultrasonic (transit-time) gauging station for the continuous measurement of discharge in a river, an open channel or a closed conduit. It also describes the basic principles on which the method is based, the operation and performance of associated instrumentation and procedures for commissioning. It is limited to the "transit time of ultrasonic pulses" technique, and is not applicable to systems that make use of the "Doppler shift" or "correlation" or "level-to-flow" techniques. ISO 6416 is not applicable to measurement in rivers with ice. NOTE ISO 6416 focuses on open channel flow measurement. IEC 60041 covers the use of the technique for full pipe flow measurement.
Description
ISO 6416 describes the establishment and operation of an ultrasonic (transit-time) gauging station for the continuous measurement of discharge in a river, an open channel or a closed conduit. It also describes the basic principles on which the method is based, the operation and performance of associated instrumentation and procedures for commissioning. It is limited to the "transit time of ultrasonic pulses" technique, and is not applicable to systems that make use of the "Doppler shift" or "correlation" or "level-to-flow" techniques. ISO 6416 is not applicable to measurement in rivers with ice. NOTE ISO 6416 focuses on open channel flow measurement. IEC 60041 covers the use of the technique for full pipe flow measurement.

Suppliers

Company
Product
Description
Supplier Links
Hydrometry - Measurement of discharge by the ultrasonic transit time (time of flight) method - ISO 6416:2017 - CSA Group
Toronto, Ontario, Canada
Hydrometry - Measurement of discharge by the ultrasonic transit time (time of flight) method
ISO 6416:2017
Hydrometry - Measurement of discharge by the ultrasonic transit time (time of flight) method ISO 6416:2017
ISO 6416 describes the establishment and operation of an ultrasonic (transit-time) gauging station for the continuous measurement of discharge in a river, an open channel or a closed conduit. It also describes the basic principles on which the method is based, the operation and performance of associated instrumentation and procedures for commissioning. It is limited to the "transit time of ultrasonic pulses" technique, and is not applicable to systems that make use of the "Doppler shift" or "correlation" or "level-to-flow" techniques. ISO 6416 is not applicable to measurement in rivers with ice. NOTE ISO 6416 focuses on open channel flow measurement. IEC 60041 covers the use of the technique for full pipe flow measurement.

ISO 6416 describes the establishment and operation of an ultrasonic (transit-time) gauging station for the continuous measurement of discharge in a river, an open channel or a closed conduit. It also describes the basic principles on which the method is based, the operation and performance of associated instrumentation and procedures for commissioning.

It is limited to the "transit time of ultrasonic pulses" technique, and is not applicable to systems that make use of the "Doppler shift" or "correlation" or "level-to-flow" techniques.

ISO 6416 is not applicable to measurement in rivers with ice.

NOTE ISO 6416 focuses on open channel flow measurement. IEC 60041 covers the use of the technique for full pipe flow measurement.

Supplier's Site