CSA Group Anaesthetic and respiratory equipment - Tracheostomy tubes and connectors ISO 5366:2016

Description
ISO 5366:2016 specifies requirements for adult and paediatric tracheostomy tubes and connectors. Such tubes are primarily designed for patients who require anaesthesia, artificial ventilation or other respiratory support. ISO 5366:2016 is also applicable to specialized tracheostomy tubes that share common attributes, for example, those without a connector at the machine end intended for spontaneously breathing patients and those with reinforced walls or tubes made of metal or tubes with shoulders, tapering tubes, tubes with provision for suctioning or monitoring or delivery of drugs or other gases. Flammability of tracheostomy tubes is a well recognized hazard (for example, when electrosurgical units or lasers are used with flammable anaesthetic agents in oxidant-enriched atmospheres) that is addressed by appropriate clinical management and is outside the scope of this International Standard. NOTE ISO/TR 11991 gives guidance on avoidance of airway fires.
Description
ISO 5366:2016 specifies requirements for adult and paediatric tracheostomy tubes and connectors. Such tubes are primarily designed for patients who require anaesthesia, artificial ventilation or other respiratory support. ISO 5366:2016 is also applicable to specialized tracheostomy tubes that share common attributes, for example, those without a connector at the machine end intended for spontaneously breathing patients and those with reinforced walls or tubes made of metal or tubes with shoulders, tapering tubes, tubes with provision for suctioning or monitoring or delivery of drugs or other gases. Flammability of tracheostomy tubes is a well recognized hazard (for example, when electrosurgical units or lasers are used with flammable anaesthetic agents in oxidant-enriched atmospheres) that is addressed by appropriate clinical management and is outside the scope of this International Standard. NOTE ISO/TR 11991 gives guidance on avoidance of airway fires.

Suppliers

Company
Product
Description
Supplier Links
Anaesthetic and respiratory equipment - Tracheostomy tubes and connectors - ISO 5366:2016 - CSA Group
Toronto, Ontario, Canada
Anaesthetic and respiratory equipment - Tracheostomy tubes and connectors
ISO 5366:2016
Anaesthetic and respiratory equipment - Tracheostomy tubes and connectors ISO 5366:2016
ISO 5366:2016 specifies requirements for adult and paediatric tracheostomy tubes and connectors. Such tubes are primarily designed for patients who require anaesthesia, artificial ventilation or other respiratory support. ISO 5366:2016 is also applicable to specialized tracheostomy tubes that share common attributes, for example, those without a connector at the machine end intended for spontaneously breathing patients and those with reinforced walls or tubes made of metal or tubes with shoulders, tapering tubes, tubes with provision for suctioning or monitoring or delivery of drugs or other gases. Flammability of tracheostomy tubes is a well recognized hazard (for example, when electrosurgical units or lasers are used with flammable anaesthetic agents in oxidant-enriched atmospheres) that is addressed by appropriate clinical management and is outside the scope of this International Standard. NOTE ISO/TR 11991 gives guidance on avoidance of airway fires.

ISO 5366:2016 specifies requirements for adult and paediatric tracheostomy tubes and connectors. Such tubes are primarily designed for patients who require anaesthesia, artificial ventilation or other respiratory support.

ISO 5366:2016 is also applicable to specialized tracheostomy tubes that share common attributes, for example, those without a connector at the machine end intended for spontaneously breathing patients and those with reinforced walls or tubes made of metal or tubes with shoulders, tapering tubes, tubes with provision for suctioning or monitoring or delivery of drugs or other gases.

Flammability of tracheostomy tubes is a well recognized hazard (for example, when electrosurgical units or lasers are used with flammable anaesthetic agents in oxidant-enriched atmospheres) that is addressed by appropriate clinical management and is outside the scope of this International Standard.

NOTE ISO/TR 11991 gives guidance on avoidance of airway fires.