CSA Group Methods for the calibration of vibration and shock pick-ups - Part 8: Primary calibration by dual centrifuge ISO 5347-8:1993

Description
Lays down detailed specifications for the instrumentation and procedure to be used for primary calibration of accelerometers using centrifuge calibration. Applies to all types of rectilinear accelerometers, primary standards and working pick-ups. Is applicable for a frequency range from 0,7 Hz to 10 Hz and a dynamic range from 10 m/s^2 to 100 m/s^2. The limits of uncertainty applicable are ± 2 % of reading.
Description
Lays down detailed specifications for the instrumentation and procedure to be used for primary calibration of accelerometers using centrifuge calibration. Applies to all types of rectilinear accelerometers, primary standards and working pick-ups. Is applicable for a frequency range from 0,7 Hz to 10 Hz and a dynamic range from 10 m/s^2 to 100 m/s^2. The limits of uncertainty applicable are ± 2 % of reading.

Suppliers

Company
Product
Description
Supplier Links
Methods for the calibration of vibration and shock pick-ups - Part 8: Primary calibration by dual centrifuge - ISO 5347-8:1993 - CSA Group
Toronto, Ontario, Canada
Methods for the calibration of vibration and shock pick-ups - Part 8: Primary calibration by dual centrifuge
ISO 5347-8:1993
Methods for the calibration of vibration and shock pick-ups - Part 8: Primary calibration by dual centrifuge ISO 5347-8:1993
Lays down detailed specifications for the instrumentation and procedure to be used for primary calibration of accelerometers using centrifuge calibration. Applies to all types of rectilinear accelerometers, primary standards and working pick-ups. Is applicable for a frequency range from 0,7 Hz to 10 Hz and a dynamic range from 10 m/s^2 to 100 m/s^2. The limits of uncertainty applicable are ± 2 % of reading.

Lays down detailed specifications for the instrumentation and procedure to be used for primary calibration of accelerometers using centrifuge calibration. Applies to all types of rectilinear accelerometers, primary standards and working pick-ups. Is applicable for a frequency range from 0,7 Hz to 10 Hz and a dynamic range from 10 m/s^2 to 100 m/s^2. The limits of uncertainty applicable are ± 2 % of reading.

Supplier's Site

Technical Specifications

  CSA Group
Product Category Standards and Technical Documents
Product Number ISO 5347-8:1993
Product Name Methods for the calibration of vibration and shock pick-ups - Part 8: Primary calibration by dual centrifuge
Unlock Full Specs