CSA Group Petroleum products - Determination of carbon residue - Ramsbottom method ISO 4262:1993

Description
The principle of the method specified is weighing a test portion into a glass coking bulb having a capillary opening and placing it in a metal furnace maintained at a temperature of approximately 550 °C, thus quickly heating the test portion to the point at which all volatile matter is evaporated out of the bulb, while the heavier residue remaining in the bulb undergoes cracking and coking reactions during a specified heating period, removing the bulb, cooling it in a desiccator and weighing again. The method may be used to determine amounts of carbon residues in the range of 0,01 % (m/m) to 30,0 % (m/m), left after evaporation and pyrolysis.
Description
The principle of the method specified is weighing a test portion into a glass coking bulb having a capillary opening and placing it in a metal furnace maintained at a temperature of approximately 550 °C, thus quickly heating the test portion to the point at which all volatile matter is evaporated out of the bulb, while the heavier residue remaining in the bulb undergoes cracking and coking reactions during a specified heating period, removing the bulb, cooling it in a desiccator and weighing again. The method may be used to determine amounts of carbon residues in the range of 0,01 % (m/m) to 30,0 % (m/m), left after evaporation and pyrolysis.

Suppliers

Company
Product
Description
Supplier Links
Petroleum products - Determination of carbon residue - Ramsbottom method - ISO 4262:1993 - CSA Group
Toronto, Ontario, Canada
Petroleum products - Determination of carbon residue - Ramsbottom method
ISO 4262:1993
Petroleum products - Determination of carbon residue - Ramsbottom method ISO 4262:1993
The principle of the method specified is weighing a test portion into a glass coking bulb having a capillary opening and placing it in a metal furnace maintained at a temperature of approximately 550 °C, thus quickly heating the test portion to the point at which all volatile matter is evaporated out of the bulb, while the heavier residue remaining in the bulb undergoes cracking and coking reactions during a specified heating period, removing the bulb, cooling it in a desiccator and weighing again. The method may be used to determine amounts of carbon residues in the range of 0,01 % (m/m) to 30,0 % (m/m), left after evaporation and pyrolysis.

The principle of the method specified is weighing a test portion into a glass coking bulb having a capillary opening and placing it in a metal furnace maintained at a temperature of approximately 550 °C, thus quickly heating the test portion to the point at which all volatile matter is evaporated out of the bulb, while the heavier residue remaining in the bulb undergoes cracking and coking reactions during a specified heating period, removing the bulb, cooling it in a desiccator and weighing again. The method may be used to determine amounts of carbon residues in the range of 0,01 % (m/m) to 30,0 % (m/m), left after evaporation and pyrolysis.

Supplier's Site

Technical Specifications

  CSA Group
Product Category Standards and Technical Documents
Product Number ISO 4262:1993
Product Name Petroleum products - Determination of carbon residue - Ramsbottom method
Unlock Full Specs
to access all available technical data

Similar Products