CSA Group Acoustics - Reference zero for the calibration of audiometric equipment - Part 8: Reference equivalent threshold sound pressure levels for pure tones and circumaural earphones ISO 389-8:2004

Description
ISO 389-8:2004 specifies reference equivalent threshold sound pressure levels (RETSPLs) for pure tones in the frequency range from 125 Hz to 8 kHz, applicable to the calibration of air conduction audiometers equipped with a particular model of circumaural earphones (SENNHEISER HDA 200). Some notes and references on the derivation and the test conditions used to determine the recommended reference levels are given in Annex A and the Bibliography. The sound attenuation of the earphone is given in Annex B. For speech audiometers of types A-E and B-E, the correction figures of the earphone for a free-field equivalent output are given in Annex C.
Description
ISO 389-8:2004 specifies reference equivalent threshold sound pressure levels (RETSPLs) for pure tones in the frequency range from 125 Hz to 8 kHz, applicable to the calibration of air conduction audiometers equipped with a particular model of circumaural earphones (SENNHEISER HDA 200). Some notes and references on the derivation and the test conditions used to determine the recommended reference levels are given in Annex A and the Bibliography. The sound attenuation of the earphone is given in Annex B. For speech audiometers of types A-E and B-E, the correction figures of the earphone for a free-field equivalent output are given in Annex C.

Suppliers

Company
Product
Description
Supplier Links
Acoustics - Reference zero for the calibration of audiometric equipment - Part 8: Reference equivalent threshold sound pressure levels for pure tones and circumaural earphones - ISO 389-8:2004 - CSA Group
Toronto, Ontario, Canada
Acoustics - Reference zero for the calibration of audiometric equipment - Part 8: Reference equivalent threshold sound pressure levels for pure tones and circumaural earphones
ISO 389-8:2004
Acoustics - Reference zero for the calibration of audiometric equipment - Part 8: Reference equivalent threshold sound pressure levels for pure tones and circumaural earphones ISO 389-8:2004
ISO 389-8:2004 specifies reference equivalent threshold sound pressure levels (RETSPLs) for pure tones in the frequency range from 125 Hz to 8 kHz, applicable to the calibration of air conduction audiometers equipped with a particular model of circumaural earphones (SENNHEISER HDA 200). Some notes and references on the derivation and the test conditions used to determine the recommended reference levels are given in Annex A and the Bibliography. The sound attenuation of the earphone is given in Annex B. For speech audiometers of types A-E and B-E, the correction figures of the earphone for a free-field equivalent output are given in Annex C.

ISO 389-8:2004 specifies reference equivalent threshold sound pressure levels (RETSPLs) for pure tones in the frequency range from 125 Hz to 8 kHz, applicable to the calibration of air conduction audiometers equipped with a particular model of circumaural earphones (SENNHEISER HDA 200).

Some notes and references on the derivation and the test conditions used to determine the recommended reference levels are given in Annex A and the Bibliography.

The sound attenuation of the earphone is given in Annex B. For speech audiometers of types A-E and B-E, the correction figures of the earphone for a free-field equivalent output are given in Annex C.