CSA Group Water for analytical laboratory use - Specification and test methods ISO 3696:1987

Description
Specifies the requirements for three grades for the analysis of inorganic chemicals. Not applicable to organic trace analysis, analysis of surface-active agents and biological or medical analysis. The material shall be a clear, colourless liquid as assessed by inspection. Classifies according to the content: free from dissolved or colloidal ionic and organic contaminants, very low inorganic, organic or colloidal contaminants and suitable for laboratory wet chemistry work. Specifies the pH and conductivity measurement, the limit tests for oxidizable matter and for reactive silica, the measurement of absorbance and the determination of residue after evaporation at 110 °C.
Description
Specifies the requirements for three grades for the analysis of inorganic chemicals. Not applicable to organic trace analysis, analysis of surface-active agents and biological or medical analysis. The material shall be a clear, colourless liquid as assessed by inspection. Classifies according to the content: free from dissolved or colloidal ionic and organic contaminants, very low inorganic, organic or colloidal contaminants and suitable for laboratory wet chemistry work. Specifies the pH and conductivity measurement, the limit tests for oxidizable matter and for reactive silica, the measurement of absorbance and the determination of residue after evaporation at 110 °C.

Suppliers

Company
Product
Description
Supplier Links
Water for analytical laboratory use - Specification and test methods - ISO 3696:1987 - CSA Group
Toronto, Ontario, Canada
Water for analytical laboratory use - Specification and test methods
ISO 3696:1987
Water for analytical laboratory use - Specification and test methods ISO 3696:1987
Specifies the requirements for three grades for the analysis of inorganic chemicals. Not applicable to organic trace analysis, analysis of surface-active agents and biological or medical analysis. The material shall be a clear, colourless liquid as assessed by inspection. Classifies according to the content: free from dissolved or colloidal ionic and organic contaminants, very low inorganic, organic or colloidal contaminants and suitable for laboratory wet chemistry work. Specifies the pH and conductivity measurement, the limit tests for oxidizable matter and for reactive silica, the measurement of absorbance and the determination of residue after evaporation at 110 °C.

Specifies the requirements for three grades for the analysis of inorganic chemicals. Not applicable to organic trace analysis, analysis of surface-active agents and biological or medical analysis. The material shall be a clear, colourless liquid as assessed by inspection. Classifies according to the content: free from dissolved or colloidal ionic and organic contaminants, very low inorganic, organic or colloidal contaminants and suitable for laboratory wet chemistry work. Specifies the pH and conductivity measurement, the limit tests for oxidizable matter and for reactive silica, the measurement of absorbance and the determination of residue after evaporation at 110 °C.

Supplier's Site

Technical Specifications

  CSA Group
Product Category Standards and Technical Documents
Product Number ISO 3696:1987
Product Name Water for analytical laboratory use - Specification and test methods
Unlock Full Specs
to access all available technical data

Similar Products