CSA Group Workplace air - Determination of metals and metalloids in airborne particulate matter by inductively coupled plasma mass spectrometry ISO 30011:2010

Description
ISO 30011:2010 specifies a procedure for the use of quadrupole inductively coupled plasma mass spectrometry (ICP‑MS) for analysing test solutions prepared from samples of airborne particulate matter collected as specified in ISO 15202‑1. Method development, performance checks, and a routine analysis method are specified. Test solutions for analysis by ISO 30011:2010 are prepared as specified in ISO 15202‑2. ISO 30011:2010 is applicable to the assessment of workplace exposure to metals and metalloids for comparison with limit values.
Description
ISO 30011:2010 specifies a procedure for the use of quadrupole inductively coupled plasma mass spectrometry (ICP‑MS) for analysing test solutions prepared from samples of airborne particulate matter collected as specified in ISO 15202‑1. Method development, performance checks, and a routine analysis method are specified. Test solutions for analysis by ISO 30011:2010 are prepared as specified in ISO 15202‑2. ISO 30011:2010 is applicable to the assessment of workplace exposure to metals and metalloids for comparison with limit values.

Suppliers

Company
Product
Description
Supplier Links
Workplace air - Determination of metals and metalloids in airborne particulate matter by inductively coupled plasma mass spectrometry - ISO 30011:2010 - CSA Group
Toronto, Ontario, Canada
Workplace air - Determination of metals and metalloids in airborne particulate matter by inductively coupled plasma mass spectrometry
ISO 30011:2010
Workplace air - Determination of metals and metalloids in airborne particulate matter by inductively coupled plasma mass spectrometry ISO 30011:2010
ISO 30011:2010 specifies a procedure for the use of quadrupole inductively coupled plasma mass spectrometry (ICP‑MS) for analysing test solutions prepared from samples of airborne particulate matter collected as specified in ISO 15202‑1. Method development, performance checks, and a routine analysis method are specified. Test solutions for analysis by ISO 30011:2010 are prepared as specified in ISO 15202‑2. ISO 30011:2010 is applicable to the assessment of workplace exposure to metals and metalloids for comparison with limit values.

ISO 30011:2010 specifies a procedure for the use of quadrupole inductively coupled plasma mass spectrometry (ICP‑MS) for analysing test solutions prepared from samples of airborne particulate matter collected as specified in ISO 15202‑1. Method development, performance checks, and a routine analysis method are specified.

Test solutions for analysis by ISO 30011:2010 are prepared as specified in ISO 15202‑2.

ISO 30011:2010 is applicable to the assessment of workplace exposure to metals and metalloids for comparison with limit values.