CSA Group Iron ores - Determination of silicon content - Part 2: Reduced molybdosilicate spectrophotometric method ISO 2598-2:1992

Description
The method is based on decomposition of the test portion by fusion with sodium tetraborate and treatment with dilute nitric acid, addition of ammonium molybdate to convert silicate into a molybdatosilicate complex, reduction to molybdenum blue with ascorbic acid, and spectrophotometric measurement of the absorbance of the molybdenum blue complex at a wavelength of approximately 600 nm. Applies to silicon contents between 0,1 % and 5,0 % in natural iron ores, iron ore concentrates and agglomerates, including sinter products, especially for ores containing fluorine.
Description
The method is based on decomposition of the test portion by fusion with sodium tetraborate and treatment with dilute nitric acid, addition of ammonium molybdate to convert silicate into a molybdatosilicate complex, reduction to molybdenum blue with ascorbic acid, and spectrophotometric measurement of the absorbance of the molybdenum blue complex at a wavelength of approximately 600 nm. Applies to silicon contents between 0,1 % and 5,0 % in natural iron ores, iron ore concentrates and agglomerates, including sinter products, especially for ores containing fluorine.

Suppliers

Company
Product
Description
Supplier Links
Iron ores - Determination of silicon content - Part 2: Reduced molybdosilicate spectrophotometric method - ISO 2598-2:1992 - CSA Group
Toronto, Ontario, Canada
Iron ores - Determination of silicon content - Part 2: Reduced molybdosilicate spectrophotometric method
ISO 2598-2:1992
Iron ores - Determination of silicon content - Part 2: Reduced molybdosilicate spectrophotometric method ISO 2598-2:1992
The method is based on decomposition of the test portion by fusion with sodium tetraborate and treatment with dilute nitric acid, addition of ammonium molybdate to convert silicate into a molybdatosilicate complex, reduction to molybdenum blue with ascorbic acid, and spectrophotometric measurement of the absorbance of the molybdenum blue complex at a wavelength of approximately 600 nm. Applies to silicon contents between 0,1 % and 5,0 % in natural iron ores, iron ore concentrates and agglomerates, including sinter products, especially for ores containing fluorine.

The method is based on decomposition of the test portion by fusion with sodium tetraborate and treatment with dilute nitric acid, addition of ammonium molybdate to convert silicate into a molybdatosilicate complex, reduction to molybdenum blue with ascorbic acid, and spectrophotometric measurement of the absorbance of the molybdenum blue complex at a wavelength of approximately 600 nm. Applies to silicon contents between 0,1 % and 5,0 % in natural iron ores, iron ore concentrates and agglomerates, including sinter products, especially for ores containing fluorine.

Supplier's Site

Technical Specifications

  CSA Group
Product Category Standards and Technical Documents
Product Number ISO 2598-2:1992
Product Name Iron ores - Determination of silicon content - Part 2: Reduced molybdosilicate spectrophotometric method
Unlock Full Specs
to access all available technical data

Similar Products