CSA Group Surface chemical analysis - Secondary-ion mass spectrometry - Repeatability and constancy of the relative-intensity scale in static secondary-ion mass spectrometry ISO 23830:2008

Description
ISO 23830:2008 specifies a method for confirming the repeatability and constancy of the positive-ion relative-intensity scale of static secondary-ion mass spectrometers, for general analytical purposes. It is only applicable to instruments that incorporate an electron gun for charge neutralization. It is not intended to be a calibration of the intensity/mass response function. That calibration may be made by the instrument manufacturer or another organization. The present method provides data to confirm the constancy of relative intensities with instrument usage. Guidance is given on some of the instrument settings that may affect this constancy.
Description
ISO 23830:2008 specifies a method for confirming the repeatability and constancy of the positive-ion relative-intensity scale of static secondary-ion mass spectrometers, for general analytical purposes. It is only applicable to instruments that incorporate an electron gun for charge neutralization. It is not intended to be a calibration of the intensity/mass response function. That calibration may be made by the instrument manufacturer or another organization. The present method provides data to confirm the constancy of relative intensities with instrument usage. Guidance is given on some of the instrument settings that may affect this constancy.

Suppliers

Company
Product
Description
Supplier Links
Surface chemical analysis - Secondary-ion mass spectrometry - Repeatability and constancy of the relative-intensity scale in static secondary-ion mass spectrometry - ISO 23830:2008 - CSA Group
Toronto, Ontario, Canada
Surface chemical analysis - Secondary-ion mass spectrometry - Repeatability and constancy of the relative-intensity scale in static secondary-ion mass spectrometry
ISO 23830:2008
Surface chemical analysis - Secondary-ion mass spectrometry - Repeatability and constancy of the relative-intensity scale in static secondary-ion mass spectrometry ISO 23830:2008
ISO 23830:2008 specifies a method for confirming the repeatability and constancy of the positive-ion relative-intensity scale of static secondary-ion mass spectrometers, for general analytical purposes. It is only applicable to instruments that incorporate an electron gun for charge neutralization. It is not intended to be a calibration of the intensity/mass response function. That calibration may be made by the instrument manufacturer or another organization. The present method provides data to confirm the constancy of relative intensities with instrument usage. Guidance is given on some of the instrument settings that may affect this constancy.

ISO 23830:2008 specifies a method for confirming the repeatability and constancy of the positive-ion relative-intensity scale of static secondary-ion mass spectrometers, for general analytical purposes. It is only applicable to instruments that incorporate an electron gun for charge neutralization. It is not intended to be a calibration of the intensity/mass response function. That calibration may be made by the instrument manufacturer or another organization. The present method provides data to confirm the constancy of relative intensities with instrument usage. Guidance is given on some of the instrument settings that may affect this constancy.

Supplier's Site

Technical Specifications

  CSA Group
Product Category Standards and Technical Documents
Product Number ISO 23830:2008
Product Name Surface chemical analysis - Secondary-ion mass spectrometry - Repeatability and constancy of the relative-intensity scale in static secondary-ion mass spectrometry
Unlock Full Specs
to access all available technical data

Similar Products