CSA Group Water quality - Determination of selected alkylphenols - Part 1: Method for non-filtered samples using liquid-liquid extraction and gas chromatography with mass selective detection ISO 18857-1:2005

Description
ISO 18857-1:2005 specifies a method for the determination of 4-nonylphenol (mixture of isomers) and 4-(1,1,3,3-tetrameth ylbutyl)phenol in non-filtered samples of drinking water, ground water and surface water. The method is applicable in a concentration range from 0,005 micrograms per litre to 0,2 micrograms per litre for 4-(1,1,3,3-tetrameth ylbutyl)phenol and from 0,02 micrograms per litre to 0,2 micrograms per litre for 4-nonylphenol (mixture of isomers). Depending on the matrix, the method is also applicable to waste water containing the analyzed compounds in the concentration range from 0,1 micrograms per litre to 50 micrograms per litre. Higher concentrations can be measured after appropriate dilution of the sample.
Description
ISO 18857-1:2005 specifies a method for the determination of 4-nonylphenol (mixture of isomers) and 4-(1,1,3,3-tetrameth ylbutyl)phenol in non-filtered samples of drinking water, ground water and surface water. The method is applicable in a concentration range from 0,005 micrograms per litre to 0,2 micrograms per litre for 4-(1,1,3,3-tetrameth ylbutyl)phenol and from 0,02 micrograms per litre to 0,2 micrograms per litre for 4-nonylphenol (mixture of isomers). Depending on the matrix, the method is also applicable to waste water containing the analyzed compounds in the concentration range from 0,1 micrograms per litre to 50 micrograms per litre. Higher concentrations can be measured after appropriate dilution of the sample.

Suppliers

Company
Product
Description
Supplier Links
Water quality - Determination of selected alkylphenols - Part 1: Method for non-filtered samples using liquid-liquid extraction and gas chromatography with mass selective detection - ISO 18857-1:2005 - CSA Group
Toronto, Ontario, Canada
Water quality - Determination of selected alkylphenols - Part 1: Method for non-filtered samples using liquid-liquid extraction and gas chromatography with mass selective detection
ISO 18857-1:2005
Water quality - Determination of selected alkylphenols - Part 1: Method for non-filtered samples using liquid-liquid extraction and gas chromatography with mass selective detection ISO 18857-1:2005
ISO 18857-1:2005 specifies a method for the determination of 4-nonylphenol (mixture of isomers) and 4-(1,1,3,3-tetrameth ylbutyl)phenol in non-filtered samples of drinking water, ground water and surface water. The method is applicable in a concentration range from 0,005 micrograms per litre to 0,2 micrograms per litre for 4-(1,1,3,3-tetrameth ylbutyl)phenol and from 0,02 micrograms per litre to 0,2 micrograms per litre for 4-nonylphenol (mixture of isomers). Depending on the matrix, the method is also applicable to waste water containing the analyzed compounds in the concentration range from 0,1 micrograms per litre to 50 micrograms per litre. Higher concentrations can be measured after appropriate dilution of the sample.

ISO 18857-1:2005 specifies a method for the determination of 4-nonylphenol (mixture of isomers) and 4-(1,1,3,3-tetramethylbutyl)phenol in non-filtered samples of drinking water, ground water and surface water. The method is applicable in a concentration range from 0,005 micrograms per litre to 0,2 micrograms per litre for 4-(1,1,3,3-tetramethylbutyl)phenol and from 0,02 micrograms per litre to 0,2 micrograms per litre for 4-nonylphenol (mixture of isomers). Depending on the matrix, the method is also applicable to waste water containing the analyzed compounds in the concentration range from 0,1 micrograms per litre to 50 micrograms per litre. Higher concentrations can be measured after appropriate dilution of the sample.

Supplier's Site

Technical Specifications

  CSA Group
Product Category Standards and Technical Documents
Product Number ISO 18857-1:2005
Product Name Water quality - Determination of selected alkylphenols - Part 1: Method for non-filtered samples using liquid-liquid extraction and gas chromatography with mass selective detection
Unlock Full Specs
to access all available technical data

Similar Products