CSA Group Surface chemical analysis - Auger electron spectroscopy and X-ray photoelectron spectroscopy - Determination of lateral resolution ISO 18516:2006

Description
ISO 18516:2006 describes three methods for measuring the lateral resolution achievable in Auger electron spectrometers and X-ray photoelectron spectrometers under defined settings. The straight-edge method is suitable for instruments where the lateral resolution is expected to be larger than 1 micrometre. The grid method is suitable if the lateral resolution is expected to be less than 1 micrometre but more than 20 nm. The gold-island method is suitable for instruments where the lateral resolution is expected to be smaller than 50 nm. Annexes A, B and C provide illustrative examples of the measurement of lateral resolution.
Description
ISO 18516:2006 describes three methods for measuring the lateral resolution achievable in Auger electron spectrometers and X-ray photoelectron spectrometers under defined settings. The straight-edge method is suitable for instruments where the lateral resolution is expected to be larger than 1 micrometre. The grid method is suitable if the lateral resolution is expected to be less than 1 micrometre but more than 20 nm. The gold-island method is suitable for instruments where the lateral resolution is expected to be smaller than 50 nm. Annexes A, B and C provide illustrative examples of the measurement of lateral resolution.

Suppliers

Company
Product
Description
Supplier Links
Surface chemical analysis - Auger electron spectroscopy and X-ray photoelectron spectroscopy - Determination of lateral resolution - ISO 18516:2006 - CSA Group
Toronto, Ontario, Canada
Surface chemical analysis - Auger electron spectroscopy and X-ray photoelectron spectroscopy - Determination of lateral resolution
ISO 18516:2006
Surface chemical analysis - Auger electron spectroscopy and X-ray photoelectron spectroscopy - Determination of lateral resolution ISO 18516:2006
ISO 18516:2006 describes three methods for measuring the lateral resolution achievable in Auger electron spectrometers and X-ray photoelectron spectrometers under defined settings. The straight-edge method is suitable for instruments where the lateral resolution is expected to be larger than 1 micrometre. The grid method is suitable if the lateral resolution is expected to be less than 1 micrometre but more than 20 nm. The gold-island method is suitable for instruments where the lateral resolution is expected to be smaller than 50 nm. Annexes A, B and C provide illustrative examples of the measurement of lateral resolution.

ISO 18516:2006 describes three methods for measuring the lateral resolution achievable in Auger electron spectrometers and X-ray photoelectron spectrometers under defined settings. The straight-edge method is suitable for instruments where the lateral resolution is expected to be larger than 1 micrometre. The grid method is suitable if the lateral resolution is expected to be less than 1 micrometre but more than 20 nm. The gold-island method is suitable for instruments where the lateral resolution is expected to be smaller than 50 nm.

Annexes A, B and C provide illustrative examples of the measurement of lateral resolution.