CSA Group Methods for the calibration of vibration and shock transducers - Part 22: Shock calibration by comparison to a reference transducer ISO 16063-22:2005

Description
ISO 16063-22:2005 specifies the instrumentation and procedures to be used for secondary shock calibration of rectilinear transducers, using a reference acceleration, velocity or force measurement for the time-dependent shock. The methods are applicable in a shock pulse duration range of 0,05 ms to 8,0 ms, and a dynamic range (peak value) of 100 m/s to 100 km/s2 (time-dependent). The methods allow the transducer shock sensitivity (i.e. the relationship between the peak values of the transducer output quantity and the acceleration) to be obtained. These methods are not intended for the calibration of dynamic force transducers used in modal analysis.
Description
ISO 16063-22:2005 specifies the instrumentation and procedures to be used for secondary shock calibration of rectilinear transducers, using a reference acceleration, velocity or force measurement for the time-dependent shock. The methods are applicable in a shock pulse duration range of 0,05 ms to 8,0 ms, and a dynamic range (peak value) of 100 m/s to 100 km/s2 (time-dependent). The methods allow the transducer shock sensitivity (i.e. the relationship between the peak values of the transducer output quantity and the acceleration) to be obtained. These methods are not intended for the calibration of dynamic force transducers used in modal analysis.

Suppliers

Company
Product
Description
Supplier Links
Methods for the calibration of vibration and shock transducers - Part 22: Shock calibration by comparison to a reference transducer - ISO 16063-22:2005 - CSA Group
Toronto, Ontario, Canada
Methods for the calibration of vibration and shock transducers - Part 22: Shock calibration by comparison to a reference transducer
ISO 16063-22:2005
Methods for the calibration of vibration and shock transducers - Part 22: Shock calibration by comparison to a reference transducer ISO 16063-22:2005
ISO 16063-22:2005 specifies the instrumentation and procedures to be used for secondary shock calibration of rectilinear transducers, using a reference acceleration, velocity or force measurement for the time-dependent shock. The methods are applicable in a shock pulse duration range of 0,05 ms to 8,0 ms, and a dynamic range (peak value) of 100 m/s to 100 km/s2 (time-dependent). The methods allow the transducer shock sensitivity (i.e. the relationship between the peak values of the transducer output quantity and the acceleration) to be obtained. These methods are not intended for the calibration of dynamic force transducers used in modal analysis.

ISO 16063-22:2005 specifies the instrumentation and procedures to be used for secondary shock calibration of rectilinear transducers, using a reference acceleration, velocity or force measurement for the time-dependent shock. The methods are applicable in a shock pulse duration range of 0,05 ms to 8,0 ms, and a dynamic range (peak value) of 100 m/s to 100 km/s2 (time-dependent). The methods allow the transducer shock sensitivity (i.e. the relationship between the peak values of the transducer output quantity and the acceleration) to be obtained.

These methods are not intended for the calibration of dynamic force transducers used in modal analysis.

Supplier's Site

Technical Specifications

  CSA Group
Product Category Standards and Technical Documents
Product Number ISO 16063-22:2005
Product Name Methods for the calibration of vibration and shock transducers - Part 22: Shock calibration by comparison to a reference transducer