CSA Group Indoor air - Part 10: Determination of the emission of volatile organic compounds from building products and furnishing - Emission test cell method ISO 16000-10:2006

Description
ISO 16000-10:2006 specifies a general laboratory test method for determination of the area specific emission rate of volatile organic compounds (VOCs) from newly produced building products or furnishing under defined climate conditions. The method can also, in principle, be applied to aged products. The emission data obtained can be used to calculate concentrations in a model room. According to the definition of an emission test cell, it is also possible to perform non-destructive emission measurements on building products on-site in buildings. However, the procedure for such measurements is not described in ISO 16000-10:2006. An example of an emission test cell is described. ISO 16000-10:2006 is also applicable to wood-based panels and other building products, in order to determine the emission rate of formaldehyde.
Description
ISO 16000-10:2006 specifies a general laboratory test method for determination of the area specific emission rate of volatile organic compounds (VOCs) from newly produced building products or furnishing under defined climate conditions. The method can also, in principle, be applied to aged products. The emission data obtained can be used to calculate concentrations in a model room. According to the definition of an emission test cell, it is also possible to perform non-destructive emission measurements on building products on-site in buildings. However, the procedure for such measurements is not described in ISO 16000-10:2006. An example of an emission test cell is described. ISO 16000-10:2006 is also applicable to wood-based panels and other building products, in order to determine the emission rate of formaldehyde.

Suppliers

Company
Product
Description
Supplier Links
Indoor air - Part 10: Determination of the emission of volatile organic compounds from building products and furnishing - Emission test cell method - ISO 16000-10:2006 - CSA Group
Toronto, Ontario, Canada
Indoor air - Part 10: Determination of the emission of volatile organic compounds from building products and furnishing - Emission test cell method
ISO 16000-10:2006
Indoor air - Part 10: Determination of the emission of volatile organic compounds from building products and furnishing - Emission test cell method ISO 16000-10:2006
ISO 16000-10:2006 specifies a general laboratory test method for determination of the area specific emission rate of volatile organic compounds (VOCs) from newly produced building products or furnishing under defined climate conditions. The method can also, in principle, be applied to aged products. The emission data obtained can be used to calculate concentrations in a model room. According to the definition of an emission test cell, it is also possible to perform non-destructive emission measurements on building products on-site in buildings. However, the procedure for such measurements is not described in ISO 16000-10:2006. An example of an emission test cell is described. ISO 16000-10:2006 is also applicable to wood-based panels and other building products, in order to determine the emission rate of formaldehyde.

ISO 16000-10:2006 specifies a general laboratory test method for determination of the area specific emission rate of volatile organic compounds (VOCs) from newly produced building products or furnishing under defined climate conditions. The method can also, in principle, be applied to aged products. The emission data obtained can be used to calculate concentrations in a model room.

According to the definition of an emission test cell, it is also possible to perform non-destructive emission measurements on building products on-site in buildings. However, the procedure for such measurements is not described in ISO 16000-10:2006. An example of an emission test cell is described.

ISO 16000-10:2006 is also applicable to wood-based panels and other building products, in order to determine the emission rate of formaldehyde.

Supplier's Site

Technical Specifications

  CSA Group
Product Category Standards and Technical Documents
Product Number ISO 16000-10:2006
Product Name Indoor air - Part 10: Determination of the emission of volatile organic compounds from building products and furnishing - Emission test cell method
Unlock Full Specs
to access all available technical data

Similar Products