CSA Group Determination of flash point - Closed cup equilibrium method ISO 1523:2002

Description
This International Standard specifies a method to determine the flash point of paints, varnishes, paint binders, solvents, petroleum or related products. This International Standard is not applicable to water-borne paints which may, however, be tested using ISO 3679. The method is suitable for use over the temperature range - 30 °C to 110 °C, depending on the use of different apparatus listed in Table 1. The interpretation of results obtained from solvent mixtures containing halogenated hydrocarbons should be considered with caution, as these mixtures can give anomalous results.
Description
This International Standard specifies a method to determine the flash point of paints, varnishes, paint binders, solvents, petroleum or related products. This International Standard is not applicable to water-borne paints which may, however, be tested using ISO 3679. The method is suitable for use over the temperature range - 30 °C to 110 °C, depending on the use of different apparatus listed in Table 1. The interpretation of results obtained from solvent mixtures containing halogenated hydrocarbons should be considered with caution, as these mixtures can give anomalous results.

Suppliers

Company
Product
Description
Supplier Links
Determination of flash point - Closed cup equilibrium method - ISO 1523:2002 - CSA Group
Toronto, Ontario, Canada
Determination of flash point - Closed cup equilibrium method
ISO 1523:2002
Determination of flash point - Closed cup equilibrium method ISO 1523:2002
This International Standard specifies a method to determine the flash point of paints, varnishes, paint binders, solvents, petroleum or related products. This International Standard is not applicable to water-borne paints which may, however, be tested using ISO 3679. The method is suitable for use over the temperature range - 30 °C to 110 °C, depending on the use of different apparatus listed in Table 1. The interpretation of results obtained from solvent mixtures containing halogenated hydrocarbons should be considered with caution, as these mixtures can give anomalous results.

This International Standard specifies a method to determine the flash point of paints, varnishes, paint binders, solvents, petroleum or related products.

This International Standard is not applicable to water-borne paints which may, however, be tested using ISO 3679.

The method is suitable for use over the temperature range - 30 °C to 110 °C, depending on the use of different apparatus listed in Table 1.

The interpretation of results obtained from solvent mixtures containing halogenated hydrocarbons should be considered with caution, as these mixtures can give anomalous results.