CSA Group Water quality - Uranium isotopes - Test method using alpha-spectrometry ISO 13166:2014

Description
ISO 13166:2014 specifies the conditions for the determination of uranium isotope activity concentration in samples of environmental water (including sea waters) using alpha-spectrometry and 232U as a yield tracer. A chemical separation is required to separate and purify uranium from a test portion of the sample. Plutonium isotopes can interfere, if present, with detectable activities in the sample. The detection limit for measurement of a test portion of about 500 ml is approximately 5 mBq · l−1 with a counting time of about 200 000 s.
Description
ISO 13166:2014 specifies the conditions for the determination of uranium isotope activity concentration in samples of environmental water (including sea waters) using alpha-spectrometry and 232U as a yield tracer. A chemical separation is required to separate and purify uranium from a test portion of the sample. Plutonium isotopes can interfere, if present, with detectable activities in the sample. The detection limit for measurement of a test portion of about 500 ml is approximately 5 mBq · l−1 with a counting time of about 200 000 s.

Suppliers

Company
Product
Description
Supplier Links
Water quality - Uranium isotopes - Test method using alpha-spectrometry - ISO 13166:2014 - CSA Group
Toronto, Ontario, Canada
Water quality - Uranium isotopes - Test method using alpha-spectrometry
ISO 13166:2014
Water quality - Uranium isotopes - Test method using alpha-spectrometry ISO 13166:2014
ISO 13166:2014 specifies the conditions for the determination of uranium isotope activity concentration in samples of environmental water (including sea waters) using alpha-spectrometry and 232U as a yield tracer. A chemical separation is required to separate and purify uranium from a test portion of the sample. Plutonium isotopes can interfere, if present, with detectable activities in the sample. The detection limit for measurement of a test portion of about 500 ml is approximately 5 mBq · l−1 with a counting time of about 200 000 s.

ISO 13166:2014 specifies the conditions for the determination of uranium isotope activity concentration in samples of environmental water (including sea waters) using alpha-spectrometry and 232U as a yield tracer. A chemical separation is required to separate and purify uranium from a test portion of the sample.

Plutonium isotopes can interfere, if present, with detectable activities in the sample.

The detection limit for measurement of a test portion of about 500 ml is approximately 5 mBq · l−1 with a counting time of about 200 000 s.

Supplier's Site

Technical Specifications

  CSA Group
Product Category Standards and Technical Documents
Product Number ISO 13166:2014
Product Name Water quality - Uranium isotopes - Test method using alpha-spectrometry
Unlock Full Specs
to access all available technical data

Similar Products