CSA Group Surface chemical analysis - Scanning-probe microscopy - Determination of cantilever normal spring constants ISO 11775:2015

Description
ISO 11775:2015 describes five of the methods for the determination of normal spring constants for atomic force microscope cantilevers to an accuracy of 5 % to 10 %. Each method is in one of the three categories of dimensional, static experimental, and dynamic experimental methods. The method chosen depends on the purpose, convenience, and instrumentation available to the analyst. For accuracies better than 5 % to 10 %, more sophisticated methods not described here are required.
Description
ISO 11775:2015 describes five of the methods for the determination of normal spring constants for atomic force microscope cantilevers to an accuracy of 5 % to 10 %. Each method is in one of the three categories of dimensional, static experimental, and dynamic experimental methods. The method chosen depends on the purpose, convenience, and instrumentation available to the analyst. For accuracies better than 5 % to 10 %, more sophisticated methods not described here are required.

Suppliers

Company
Product
Description
Supplier Links
Surface chemical analysis - Scanning-probe microscopy - Determination of cantilever normal spring constants - ISO 11775:2015 - CSA Group
Toronto, Ontario, Canada
Surface chemical analysis - Scanning-probe microscopy - Determination of cantilever normal spring constants
ISO 11775:2015
Surface chemical analysis - Scanning-probe microscopy - Determination of cantilever normal spring constants ISO 11775:2015
ISO 11775:2015 describes five of the methods for the determination of normal spring constants for atomic force microscope cantilevers to an accuracy of 5 % to 10 %. Each method is in one of the three categories of dimensional, static experimental, and dynamic experimental methods. The method chosen depends on the purpose, convenience, and instrumentation available to the analyst. For accuracies better than 5 % to 10 %, more sophisticated methods not described here are required.

ISO 11775:2015 describes five of the methods for the determination of normal spring constants for atomic force microscope cantilevers to an accuracy of 5 % to 10 %. Each method is in one of the three categories of dimensional, static experimental, and dynamic experimental methods. The method chosen depends on the purpose, convenience, and instrumentation available to the analyst. For accuracies better than 5 % to 10 %, more sophisticated methods not described here are required.

Supplier's Site

Technical Specifications

  CSA Group
Product Category Standards and Technical Documents
Product Number ISO 11775:2015
Product Name Surface chemical analysis - Scanning-probe microscopy - Determination of cantilever normal spring constants
Unlock Full Specs
to access all available technical data

Similar Products