CSA Group Hydrometry - Velocity-area methods using current-meters - Collection and processing of data for determination of uncertainties in flow measurement ISO 1088:2007

Description
ISO 1088:2007 provides a standard basis for the collection and processing of data for the determination of the uncertainties in measurements of discharge in open channels by velocity-area methods using current meters. To determine the discharge in open channels by the velocity-area method, components of the flow (velocity, depth and breadth) need to be measured. The component measurements are combined to compute the total discharge. The total uncertainty in the computed discharge is a combination of the uncertainties in the measured components. ISO 1088:2007 is intended to be applied to velocity-area methods that involve measurement of point velocities at a relatively small number of discrete depths and transverse positions in the flow cross-section, as described in ISO 748. It is not intended to be applied to measurements made by Acoustic Doppler Velocity Profilers (ADVP) or other instruments that produce essentially continuous velocity profiles of the flow field.
Description
ISO 1088:2007 provides a standard basis for the collection and processing of data for the determination of the uncertainties in measurements of discharge in open channels by velocity-area methods using current meters. To determine the discharge in open channels by the velocity-area method, components of the flow (velocity, depth and breadth) need to be measured. The component measurements are combined to compute the total discharge. The total uncertainty in the computed discharge is a combination of the uncertainties in the measured components. ISO 1088:2007 is intended to be applied to velocity-area methods that involve measurement of point velocities at a relatively small number of discrete depths and transverse positions in the flow cross-section, as described in ISO 748. It is not intended to be applied to measurements made by Acoustic Doppler Velocity Profilers (ADVP) or other instruments that produce essentially continuous velocity profiles of the flow field.

Suppliers

Company
Product
Description
Supplier Links
Hydrometry - Velocity-area methods using current-meters - Collection and processing of data for determination of uncertainties in flow measurement - ISO 1088:2007 - CSA Group
Toronto, Ontario, Canada
Hydrometry - Velocity-area methods using current-meters - Collection and processing of data for determination of uncertainties in flow measurement
ISO 1088:2007
Hydrometry - Velocity-area methods using current-meters - Collection and processing of data for determination of uncertainties in flow measurement ISO 1088:2007
ISO 1088:2007 provides a standard basis for the collection and processing of data for the determination of the uncertainties in measurements of discharge in open channels by velocity-area methods using current meters. To determine the discharge in open channels by the velocity-area method, components of the flow (velocity, depth and breadth) need to be measured. The component measurements are combined to compute the total discharge. The total uncertainty in the computed discharge is a combination of the uncertainties in the measured components. ISO 1088:2007 is intended to be applied to velocity-area methods that involve measurement of point velocities at a relatively small number of discrete depths and transverse positions in the flow cross-section, as described in ISO 748. It is not intended to be applied to measurements made by Acoustic Doppler Velocity Profilers (ADVP) or other instruments that produce essentially continuous velocity profiles of the flow field.

ISO 1088:2007 provides a standard basis for the collection and processing of data for the determination of the uncertainties in measurements of discharge in open channels by velocity-area methods using current meters. To determine the discharge in open channels by the velocity-area method, components of the flow (velocity, depth and breadth) need to be measured. The component measurements are combined to compute the total discharge. The total uncertainty in the computed discharge is a combination of the uncertainties in the measured components.

ISO 1088:2007 is intended to be applied to velocity-area methods that involve measurement of point velocities at a relatively small number of discrete depths and transverse positions in the flow cross-section, as described in ISO 748. It is not intended to be applied to measurements made by Acoustic Doppler Velocity Profilers (ADVP) or other instruments that produce essentially continuous velocity profiles of the flow field.

Supplier's Site

Technical Specifications

  CSA Group
Product Category Standards and Technical Documents
Product Number ISO 1088:2007
Product Name Hydrometry - Velocity-area methods using current-meters - Collection and processing of data for determination of uncertainties in flow measurement
Unlock Full Specs
to access all available technical data

Similar Products