CSA Group Medical electrical equipment - Part 2-71: Particular requirements for the basic safety and essential performance of functional near-infrared spectroscopy (NIRS) equipment IEC 80601-2-71:2015

Description
IEC 80601-2-71:2015 applies to the basic safety and essential performance of functional NIRS equipment intended to be used by themselves, or as a part of an ME system, for the production of functional NIRS equipment output for adjunctive diagnostic purposes, hereinafter referred to as ME equipment.
Description
IEC 80601-2-71:2015 applies to the basic safety and essential performance of functional NIRS equipment intended to be used by themselves, or as a part of an ME system, for the production of functional NIRS equipment output for adjunctive diagnostic purposes, hereinafter referred to as ME equipment.

Suppliers

Company
Product
Description
Supplier Links
Medical electrical equipment - Part 2-71: Particular requirements for the basic safety and essential performance of functional near-infrared spectroscopy (NIRS) equipment - IEC 80601-2-71:2015 - CSA Group
Toronto, Ontario, Canada
Medical electrical equipment - Part 2-71: Particular requirements for the basic safety and essential performance of functional near-infrared spectroscopy (NIRS) equipment
IEC 80601-2-71:2015
Medical electrical equipment - Part 2-71: Particular requirements for the basic safety and essential performance of functional near-infrared spectroscopy (NIRS) equipment IEC 80601-2-71:2015
IEC 80601-2-71:2015 applies to the basic safety and essential performance of functional NIRS equipment intended to be used by themselves, or as a part of an ME system, for the production of functional NIRS equipment output for adjunctive diagnostic purposes, hereinafter referred to as ME equipment.

IEC 80601-2-71:2015 applies to the basic safety and essential performance of functional NIRS equipment intended to be used by themselves, or as a part of an ME system, for the production of functional NIRS equipment output for adjunctive diagnostic purposes, hereinafter referred to as ME equipment.

Supplier's Site
Medical electrical equipment - Part 2-71: Particular requirements for the basic safety and essential performance of functional Near-Infrared Spectroscopy (NIRS) equipment - IEC 80601-2-71:2015 - CSA Group
Toronto, Ontario, Canada
Medical electrical equipment - Part 2-71: Particular requirements for the basic safety and essential performance of functional Near-Infrared Spectroscopy (NIRS) equipment
IEC 80601-2-71:2015
Medical electrical equipment - Part 2-71: Particular requirements for the basic safety and essential performance of functional Near-Infrared Spectroscopy (NIRS) equipment IEC 80601-2-71:2015
IEC 62366-1:2015 specifies a PROCESS for a MANUFACTURER to analyse, specify, develop and evaluate the USABILITY of a MEDICAL DEVICE as it relates to SAFETY. This USABILITY ENGINEERING (HUMAN FACTORS ENGINEERING) PROCESS permits the MANUFACTURER to assess and mitigate RISKS associated with CORRECT USE and USE ERRORS, i.e., NORMAL USE. It can be used to identify but does not assess or mitigate RISKS associated with ABNORMAL USE. This first edition of IEC 62366-1, together with the first edition of IEC 62366-2, cancels and replaces the first edition of IEC 62366 published in 2007 and its Amendment 1 (2014). Part 1 has been updated to include contemporary concepts of usability engineering, while also streamlining the process. It strengthens links to ISO 14971:2007 and the related methods of risk management as applied to safety related aspects of medical device user interfaces. Part 2 contains tutorial information to assist manufactures in complying with Part 1, as well as offering more detailed descriptions of usability engineering methods that can be applied more generally to medical devices that go beyond safety-related aspects of medical device user interfaces.

IEC 62366-1:2015 specifies a PROCESS for a MANUFACTURER to analyse, specify, develop and evaluate the USABILITY of a MEDICAL DEVICE as it relates to SAFETY. This USABILITY ENGINEERING (HUMAN FACTORS ENGINEERING) PROCESS permits the MANUFACTURER to assess and mitigate RISKS associated with CORRECT USE and USE ERRORS, i.e., NORMAL USE. It can be used to identify but does not assess or mitigate RISKS associated with ABNORMAL USE. This first edition of IEC 62366-1, together with the first edition of IEC 62366-2, cancels and replaces the first edition of IEC 62366 published in 2007 and its Amendment 1 (2014). Part 1 has been updated to include contemporary concepts of usability engineering, while also streamlining the process. It strengthens links to ISO 14971:2007 and the related methods of risk management as applied to safety related aspects of medical device user interfaces. Part 2 contains tutorial information to assist manufactures in complying with Part 1, as well as offering more detailed descriptions of usability engineering methods that can be applied more generally to medical devices that go beyond safety-related aspects of medical device user interfaces.