CSA Group Determination of certain substances in electrotechnical products - Part 7-2: Hexavalent chromium - Determination of hexavalent chromium (Cr(VI)) in polymers and electronics by the colorimetric method IEC 62321-7-2:2017

Description
IEC 62321-7-2:2017 describes procedures to measure hexavalent chromium, Cr(VI), quantitatively in samples of polymers and electronics. This method employs organic solvent to dissolve or swell the sample matrix, followed by an alkaline digestion procedure to extract Cr(VI) from samples. Studies have shown that organic/alkaline solution is more effective than acidic solution in extracting Cr(VI) from soluble and insoluble samples. Minimal reduction of Cr(VI) to Cr(III) or oxidation of Cr(III) to Cr(VI) occurs under alkaline conditions. The first edition of IEC 62321:2008 was a ‘stand-alone’ standard that included an introduction, an overview of test methods, a mechanical sample preparation as well as various test method clauses. This first edition of IEC 62321-7-2 is a partial replacement of IEC 62321:2008, forming a structural revision and generally replacing Annex C. IEC 62321-7-2 is the final replacement part of the corresponding clauses in IEC 62321:2008.
Description
IEC 62321-7-2:2017 describes procedures to measure hexavalent chromium, Cr(VI), quantitatively in samples of polymers and electronics. This method employs organic solvent to dissolve or swell the sample matrix, followed by an alkaline digestion procedure to extract Cr(VI) from samples. Studies have shown that organic/alkaline solution is more effective than acidic solution in extracting Cr(VI) from soluble and insoluble samples. Minimal reduction of Cr(VI) to Cr(III) or oxidation of Cr(III) to Cr(VI) occurs under alkaline conditions. The first edition of IEC 62321:2008 was a ‘stand-alone’ standard that included an introduction, an overview of test methods, a mechanical sample preparation as well as various test method clauses. This first edition of IEC 62321-7-2 is a partial replacement of IEC 62321:2008, forming a structural revision and generally replacing Annex C. IEC 62321-7-2 is the final replacement part of the corresponding clauses in IEC 62321:2008.

Suppliers

Company
Product
Description
Supplier Links
Determination of certain substances in electrotechnical products - Part 7-2: Hexavalent chromium - Determination of hexavalent chromium (Cr(VI)) in polymers and electronics by the colorimetric method - IEC 62321-7-2:2017 - CSA Group
Toronto, Ontario, Canada
Determination of certain substances in electrotechnical products - Part 7-2: Hexavalent chromium - Determination of hexavalent chromium (Cr(VI)) in polymers and electronics by the colorimetric method
IEC 62321-7-2:2017
Determination of certain substances in electrotechnical products - Part 7-2: Hexavalent chromium - Determination of hexavalent chromium (Cr(VI)) in polymers and electronics by the colorimetric method IEC 62321-7-2:2017
IEC 62321-7-2:2017 describes procedures to measure hexavalent chromium, Cr(VI), quantitatively in samples of polymers and electronics. This method employs organic solvent to dissolve or swell the sample matrix, followed by an alkaline digestion procedure to extract Cr(VI) from samples. Studies have shown that organic/alkaline solution is more effective than acidic solution in extracting Cr(VI) from soluble and insoluble samples. Minimal reduction of Cr(VI) to Cr(III) or oxidation of Cr(III) to Cr(VI) occurs under alkaline conditions. The first edition of IEC 62321:2008 was a ‘stand-alone’ standard that included an introduction, an overview of test methods, a mechanical sample preparation as well as various test method clauses. This first edition of IEC 62321-7-2 is a partial replacement of IEC 62321:2008, forming a structural revision and generally replacing Annex C. IEC 62321-7-2 is the final replacement part of the corresponding clauses in IEC 62321:2008.

IEC 62321-7-2:2017 describes procedures to measure hexavalent chromium, Cr(VI), quantitatively in samples of polymers and electronics. This method employs organic solvent to dissolve or swell the sample matrix, followed by an alkaline digestion procedure to extract Cr(VI) from samples. Studies have shown that organic/alkaline solution is more effective than acidic solution in extracting Cr(VI) from soluble and insoluble samples. Minimal reduction of Cr(VI) to Cr(III) or oxidation of Cr(III) to Cr(VI) occurs under alkaline conditions. The first edition of IEC 62321:2008 was a ‘stand-alone’ standard that included an introduction, an overview of test methods, a mechanical sample preparation as well as various test method clauses. This first edition of IEC 62321-7-2 is a partial replacement of IEC 62321:2008, forming a structural revision and generally replacing Annex C. IEC 62321-7-2 is the final replacement part of the corresponding clauses in IEC 62321:2008.

Supplier's Site

Technical Specifications

  CSA Group
Product Category Standards and Technical Documents
Product Number IEC 62321-7-2:2017
Product Name Determination of certain substances in electrotechnical products - Part 7-2: Hexavalent chromium - Determination of hexavalent chromium (Cr(VI)) in polymers and electronics by the colorimetric method
Unlock Full Specs
to access all available technical data

Similar Products