CSA Group (eBook Version) Gas-fired air conditioning GAS TRADE: UNIT 28 eBook

Description
CSA Group's 2015 Gas Trade materials reference the Red Seal Program's trade outlines for your preparation to become a nationally recognized gasfitter. Please visit the Red Seal Program's website for more details. Unit 27A - Commercial/Industria l appliances over 400 000 Btu/h (120 kW) Purpose: The gas technician/fitter will encounter a variety of commercial and industrial equipment over 400 000 Btu/h (120 kW) for installation or start-up. When installing such equipment the technician/fitter must follow the CSA B149.1 Natural Gas and Propane Installation Code. Start-up procedures for equipment over 400 000 Btu/h (120 kW) are determined by the equipment itself and by the manufacturer's guidelines. It is important that the gas technician/fitter be familiar with these procedures, as well as with the special requirements for piping, ventilation, venting, water treatment, etc; and some key servicing and maintenance requirements of large installations. Learning Objectives: At the end of this unit you will be able to: Describe gas piping requirements. Describe ventilation and combustion air requirements. Describe venting requirements. Identify installation requirements. Describe activation procedures for commercial/industria l appliances. Describe servicing, maintenance, and troubleshooting procedures. Identify water treatment requirements.
Description
CSA Group's 2015 Gas Trade materials reference the Red Seal Program's trade outlines for your preparation to become a nationally recognized gasfitter. Please visit the Red Seal Program's website for more details. Unit 27A - Commercial/Industria l appliances over 400 000 Btu/h (120 kW) Purpose: The gas technician/fitter will encounter a variety of commercial and industrial equipment over 400 000 Btu/h (120 kW) for installation or start-up. When installing such equipment the technician/fitter must follow the CSA B149.1 Natural Gas and Propane Installation Code. Start-up procedures for equipment over 400 000 Btu/h (120 kW) are determined by the equipment itself and by the manufacturer's guidelines. It is important that the gas technician/fitter be familiar with these procedures, as well as with the special requirements for piping, ventilation, venting, water treatment, etc; and some key servicing and maintenance requirements of large installations. Learning Objectives: At the end of this unit you will be able to: Describe gas piping requirements. Describe ventilation and combustion air requirements. Describe venting requirements. Identify installation requirements. Describe activation procedures for commercial/industria l appliances. Describe servicing, maintenance, and troubleshooting procedures. Identify water treatment requirements.

Suppliers

Company
Product
Description
Supplier Links
(eBook Version) Gas-fired air conditioning - GAS TRADE: UNIT 28 eBook - CSA Group
Toronto, Ontario, Canada
(eBook Version) Gas-fired air conditioning
GAS TRADE: UNIT 28 eBook
(eBook Version) Gas-fired air conditioning GAS TRADE: UNIT 28 eBook
CSA Group's 2015 Gas Trade materials reference the Red Seal Program's trade outlines for your preparation to become a nationally recognized gasfitter. Please visit the Red Seal Program's website for more details. Unit 27A - Commercial/Industria l appliances over 400 000 Btu/h (120 kW) Purpose: The gas technician/fitter will encounter a variety of commercial and industrial equipment over 400 000 Btu/h (120 kW) for installation or start-up. When installing such equipment the technician/fitter must follow the CSA B149.1 Natural Gas and Propane Installation Code. Start-up procedures for equipment over 400 000 Btu/h (120 kW) are determined by the equipment itself and by the manufacturer's guidelines. It is important that the gas technician/fitter be familiar with these procedures, as well as with the special requirements for piping, ventilation, venting, water treatment, etc; and some key servicing and maintenance requirements of large installations. Learning Objectives: At the end of this unit you will be able to: Describe gas piping requirements. Describe ventilation and combustion air requirements. Describe venting requirements. Identify installation requirements. Describe activation procedures for commercial/industria l appliances. Describe servicing, maintenance, and troubleshooting procedures. Identify water treatment requirements.

CSA Group's 2015 Gas Trade materials reference the Red Seal Program's trade outlines for your preparation to become a nationally recognized gasfitter. Please visit the Red Seal Program's website for more details.
Unit 27A - Commercial/Industrial appliances over 400 000 Btu/h (120 kW)
Purpose:
The gas technician/fitter will encounter a variety of commercial and industrial equipment over 400 000 Btu/h (120 kW) for installation or start-up. When installing such equipment the technician/fitter must follow the CSA B149.1 Natural Gas and Propane Installation Code. Start-up procedures for equipment over 400 000 Btu/h (120 kW) are determined by the equipment itself and by the manufacturer's guidelines. It is important that the gas technician/fitter be familiar with these procedures, as well as with the special requirements for piping, ventilation, venting, water treatment, etc; and some key servicing and maintenance requirements of large installations.
Learning Objectives:
At the end of this unit you will be able to:

  • Describe gas piping requirements.
  • Describe ventilation and combustion air requirements.
  • Describe venting requirements.
  • Identify installation requirements.
  • Describe activation procedures for commercial/industrial appliances.
  • Describe servicing, maintenance, and troubleshooting procedures.
  • Identify water treatment requirements.
Supplier's Site

Technical Specifications

  CSA Group
Product Category Standards and Technical Documents
Product Number GAS TRADE: UNIT 28 eBook
Product Name (eBook Version) Gas-fired air conditioning
Unlock Full Specs
to access all available technical data

Similar Products