Conax Technologies Sterimaster® Chamber/Load Sensor Assembly

Description
The environmental conditions found in pharmaceutical autoclave chambers are extreme for any equipment. These conditions are a major cause of sensor failure in chamber/load probes due to the ingress of moisture into the sensor and the unacceptable leakage of steam/condensate through the bulkhead connection. The Sterimaster® Chamber/Load Sensor has been designed to withstand these conditions and offers a reliability factor surpassing anything previously obtainable. Every weld undergoes NDT examination and each completed assembly is leak tested. Sterimaster® is a registered trademark of Conax Technologies
Request a Quote
Description
The environmental conditions found in pharmaceutical autoclave chambers are extreme for any equipment. These conditions are a major cause of sensor failure in chamber/load probes due to the ingress of moisture into the sensor and the unacceptable leakage of steam/condensate through the bulkhead connection. The Sterimaster® Chamber/Load Sensor has been designed to withstand these conditions and offers a reliability factor surpassing anything previously obtainable. Every weld undergoes NDT examination and each completed assembly is leak tested. Sterimaster® is a registered trademark of Conax Technologies
Request a Quote

Suppliers

Company
Product
Description
Supplier Links
Sterimaster® Chamber/Load Sensor Assembly -  - Conax Technologies
Buffalo, NY, United States
Sterimaster® Chamber/Load Sensor Assembly
Sterimaster® Chamber/Load Sensor Assembly
The environmental conditions found in pharmaceutical autoclave chambers are extreme for any equipment. These conditions are a major cause of sensor failure in chamber/load probes due to the ingress of moisture into the sensor and the unacceptable leakage of steam/condensate through the bulkhead connection. The Sterimaster® Chamber/Load Sensor has been designed to withstand these conditions and offers a reliability factor surpassing anything previously obtainable. Every weld undergoes NDT examination and each completed assembly is leak tested. Sterimaster® is a registered trademark of Conax Technologies

The environmental conditions found in pharmaceutical autoclave chambers are extreme for any equipment. These conditions are a major cause of sensor failure in chamber/load probes due to the ingress of moisture into the sensor and the unacceptable leakage of steam/condensate through the bulkhead connection.

The Sterimaster® Chamber/Load Sensor has been designed to withstand these conditions and offers a reliability factor surpassing anything previously obtainable. Every weld undergoes NDT examination and each completed assembly is leak tested.

Sterimaster® is a registered trademark of Conax Technologies

Supplier's Site

Technical Specifications

  Conax Technologies
Product Category RTD Temperature Probes
Product Name Sterimaster® Chamber/Load Sensor Assembly
Sensed Temperature -58 to 302 F (-50 to 150 C)
Element Material Platinum
Reference Resistance 100 Ohms (Most Common)
# of Lead Wires Per Element 3; 4
Element Configuration Single Element; Double Element