Cleaver-Brooks Integrated Boiler Control Hawk 6000

Description
This complete boiler control system meets institutional and industrial market specifications for North America standards. A simple and user friendly interface provides access to the latest combustion control logics; benefiting from years of proven engineering experience developed for the petrochemical and utility markets. All commissioning can be performed through the HMI. Inputs and outputs have been pre-characterized to obtain linear response at all boiler loads and avoid tedious f(x) entries. The result is unsurpassed performance when coupled with a CB industrial burner system. All Hawk 6000 systems include Ethernet communication, first out and alarm history, local or remote steam demand and much more. Features Fireye (CB120E) based integrated burner management system. Allen-Bradley Panelview Plus 10” color touch screen HMI for setup, monitoring and data acquisition using latest display ergonomics. Pre-configured and fully tested at our facility before shipment. Commissioning tuning done from the HMI including our new fully metered fast setup procedure. ISA (International Society for Automation) standard used for symbol labeling of the HMI and documents. Nema 12 Industrial grade enclosure (Nema 4 or 4X in option) wall-mounted or free-standing. NFPA 85 – 2011 or CSA B149.3 compliance Professionally assembled and pre-wired internal components compliant with UL/CSA Standards for industrial control enclosure. Supplied with a complete set of documents meeting the industry standards After sale support by factory control system engineer and/or Field service technician. Training program available.
Datasheet
Description
This complete boiler control system meets institutional and industrial market specifications for North America standards. A simple and user friendly interface provides access to the latest combustion control logics; benefiting from years of proven engineering experience developed for the petrochemical and utility markets. All commissioning can be performed through the HMI. Inputs and outputs have been pre-characterized to obtain linear response at all boiler loads and avoid tedious f(x) entries. The result is unsurpassed performance when coupled with a CB industrial burner system. All Hawk 6000 systems include Ethernet communication, first out and alarm history, local or remote steam demand and much more. Features Fireye (CB120E) based integrated burner management system. Allen-Bradley Panelview Plus 10” color touch screen HMI for setup, monitoring and data acquisition using latest display ergonomics. Pre-configured and fully tested at our facility before shipment. Commissioning tuning done from the HMI including our new fully metered fast setup procedure. ISA (International Society for Automation) standard used for symbol labeling of the HMI and documents. Nema 12 Industrial grade enclosure (Nema 4 or 4X in option) wall-mounted or free-standing. NFPA 85 – 2011 or CSA B149.3 compliance Professionally assembled and pre-wired internal components compliant with UL/CSA Standards for industrial control enclosure. Supplied with a complete set of documents meeting the industry standards After sale support by factory control system engineer and/or Field service technician. Training program available.
Datasheet

Suppliers

Company
Product
Description
Supplier Links
Integrated Boiler Control - Hawk 6000 - Cleaver-Brooks
Thomasville, GA, United States
Integrated Boiler Control
Hawk 6000
Integrated Boiler Control Hawk 6000
This complete boiler control system meets institutional and industrial market specifications for North America standards. A simple and user friendly interface provides access to the latest combustion control logics; benefiting from years of proven engineering experience developed for the petrochemical and utility markets. All commissioning can be performed through the HMI. Inputs and outputs have been pre-characterized to obtain linear response at all boiler loads and avoid tedious f(x) entries. The result is unsurpassed performance when coupled with a CB industrial burner system. All Hawk 6000 systems include Ethernet communication, first out and alarm history, local or remote steam demand and much more. Features Fireye (CB120E) based integrated burner management system. Allen-Bradley Panelview Plus 10” color touch screen HMI for setup, monitoring and data acquisition using latest display ergonomics. Pre-configured and fully tested at our facility before shipment. Commissioning tuning done from the HMI including our new fully metered fast setup procedure. ISA (International Society for Automation) standard used for symbol labeling of the HMI and documents. Nema 12 Industrial grade enclosure (Nema 4 or 4X in option) wall-mounted or free-standing. NFPA 85 – 2011 or CSA B149.3 compliance Professionally assembled and pre-wired internal components compliant with UL/CSA Standards for industrial control enclosure. Supplied with a complete set of documents meeting the industry standards After sale support by factory control system engineer and/or Field service technician. Training program available.

This complete boiler control system meets institutional and industrial market specifications for North America standards. A simple and user friendly interface provides access to the latest combustion control logics; benefiting from years of proven engineering experience developed for the petrochemical and utility markets. All commissioning can be performed through the HMI. Inputs and outputs have been pre-characterized to obtain linear response at all boiler loads and avoid tedious f(x) entries.

The result is unsurpassed performance when coupled with a CB industrial burner system. All Hawk 6000 systems include Ethernet communication, first out and alarm history, local or remote steam demand and much more.

Features

  • Fireye (CB120E) based integrated burner management system.
  • Allen-Bradley Panelview Plus 10” color touch screen HMI for setup, monitoring and data acquisition using latest display ergonomics.
  • Pre-configured and fully tested at our facility before shipment.
  • Commissioning tuning done from the HMI including our new fully metered fast setup procedure.
  • ISA (International Society for Automation) standard used for symbol labeling of the HMI and documents.
  • Nema 12 Industrial grade enclosure (Nema 4 or 4X in option) wall-mounted or free-standing.
  • NFPA 85 – 2011 or CSA B149.3 compliance
  • Professionally assembled and pre-wired internal components compliant with UL/CSA Standards for industrial control enclosure.
  • Supplied with a complete set of documents meeting the industry standards
  • After sale support by factory control system engineer and/or Field service technician.
  • Training program available.
Supplier's Site Datasheet

Technical Specifications

  Cleaver-Brooks
Product Category Boiler Controllers
Product Number Hawk 6000
Product Name Integrated Boiler Control
Controller Type Boiler
Unlock Full Specs
to access all available technical data

Similar Products

Boiler Controller - WBL410 - Iwaki America and Walchem, IWAKI America Inc
Iwaki America and Walchem, IWAKI America Inc
Specs
Controller Type Boiler
Control PID
Features Multi-Function; Rate Indication/ Control
View Details
Integrated Boiler Control - Hawk 5000 - Cleaver-Brooks
Specs
Controller Type Boiler
Control Limit
Features PLC; Datalogger
View Details
FuelMizer™ SR501-OR-4 Switching Relay with Outdoor Reset -  - Taco Comfort Solutions
Specs
Controller Type Boiler
Control Signal Switched Output
View Details
Boiler Level Controller - LC2650 - Spirax-Sarco
Specs
Controller Type Boiler
Control Limit
Form Factor Chassis; DIN
View Details