Fisher-Klosterman Fabric Collector Dust Collector

Description
True downflow, with drop-out chamber directly into the hopper. All of the air to be cleaned does not have to pass through the bottom of the bags, as in a conventional baghouse, so “can” velocity, or "interstitial" velocity is not a concern. Dirty air does not impinge on top of the filter elements as in some so called “down flow” collectors. All maintenance is done from the front, i.e. the timer, cleaning mechanism and filter change-out. Typical cartridge filter units must have access-front for filter cartridge removal, and access-back for cleaning mechanism. The back of the unit is completely usable, if required, for explosion relief venting. Horizontal pleated filter elements (PFE), means smaller height requirements. We can often fit inside rooms with low ceiling heights. We do not have to stick out over the top of buildings. For comparable volume (CFM) collectors, our floor space requirements are less, anywhere from 21% to 39% less. Smaller height and smaller floor space, translates into less physical volume saving valuable factory space. Uses the filter of the future. Pleated spun bond polyester media.
Description
True downflow, with drop-out chamber directly into the hopper. All of the air to be cleaned does not have to pass through the bottom of the bags, as in a conventional baghouse, so “can” velocity, or "interstitial" velocity is not a concern. Dirty air does not impinge on top of the filter elements as in some so called “down flow” collectors. All maintenance is done from the front, i.e. the timer, cleaning mechanism and filter change-out. Typical cartridge filter units must have access-front for filter cartridge removal, and access-back for cleaning mechanism. The back of the unit is completely usable, if required, for explosion relief venting. Horizontal pleated filter elements (PFE), means smaller height requirements. We can often fit inside rooms with low ceiling heights. We do not have to stick out over the top of buildings. For comparable volume (CFM) collectors, our floor space requirements are less, anywhere from 21% to 39% less. Smaller height and smaller floor space, translates into less physical volume saving valuable factory space. Uses the filter of the future. Pleated spun bond polyester media.

Suppliers

Company
Product
Description
Supplier Links
Fabric Collector - Dust Collector - Fisher-Klosterman
Louisville, KY, USA
Fabric Collector
Dust Collector
Fabric Collector Dust Collector
True downflow, with drop-out chamber directly into the hopper. All of the air to be cleaned does not have to pass through the bottom of the bags, as in a conventional baghouse, so “can” velocity, or "interstitial" velocity is not a concern. Dirty air does not impinge on top of the filter elements as in some so called “down flow” collectors. All maintenance is done from the front, i.e. the timer, cleaning mechanism and filter change-out. Typical cartridge filter units must have access-front for filter cartridge removal, and access-back for cleaning mechanism. The back of the unit is completely usable, if required, for explosion relief venting. Horizontal pleated filter elements (PFE), means smaller height requirements. We can often fit inside rooms with low ceiling heights. We do not have to stick out over the top of buildings. For comparable volume (CFM) collectors, our floor space requirements are less, anywhere from 21% to 39% less. Smaller height and smaller floor space, translates into less physical volume saving valuable factory space. Uses the filter of the future. Pleated spun bond polyester media.
  • True downflow, with drop-out chamber directly into the hopper. All of the air to be cleaned does not have to pass through the bottom of the bags, as in a conventional baghouse, so “can” velocity, or "interstitial" velocity is not a concern. Dirty air does not impinge on top of the filter elements as in some so called “down flow” collectors.
  • All maintenance is done from the front, i.e. the timer, cleaning mechanism and filter change-out. Typical cartridge filter units must have access-front for filter cartridge removal, and access-back for cleaning mechanism.
  • The back of the unit is completely usable, if required, for explosion relief venting.
  • Horizontal pleated filter elements (PFE), means smaller height requirements. We can often fit inside rooms with low ceiling heights. We do not have to stick out over the top of buildings.
  • For comparable volume (CFM) collectors, our floor space requirements are less, anywhere from 21% to 39% less.
  • Smaller height and smaller floor space, translates into less physical volume saving valuable factory space.
  • Uses the filter of the future. Pleated spun bond polyester media.
Supplier's Site

Technical Specifications

  Fisher-Klosterman
Product Category Dust Collectors and Dust Collector Filters
Product Number Dust Collector
Product Name Fabric Collector
Unlock Full Specs
to access all available technical data

Similar Products

Amtech ATH Horizontal Cartridge Collectors - Amtech ATH 3-18 - Clean Air Industries
Specs
Applications Abrasives; FinePowders; Metalworking Chips / Fluid; Welding Fumes
Separation / Filtration System Cartridge-type units; Fire Retardant 80/20 Cellulose/Polyester 26"x13.88 99.5% @ 0.5 microns (18x)
Airflow 4500 to 9000 SCFM (7649 to 15298 m³/hr)
View Details
High Efficiency Cyclones -  - Ducon Environmental Systems 
Ducon Environmental Systems 
Specs
Process Dry Type
Separation / Filtration System Cyclone (Centrifugal) Separator
Efficiency 99 %
View Details
Gold Series High Vacuum Dust Collectors -  - Camfil
Specs
Collector Type Stationary Unit
Process Dry Type
View Details
Torit® PowerCore® Dust Collector - VH 1-4 - Donaldson Torit – Donaldson Company, Inc.
Donaldson Torit – Donaldson Company, Inc.
Specs
Collector Type Stationary Unit
Applications Abrasives; FinePowders
Process Dry Type
View Details