This specification covers the chemical, mechanical, and metallurgical requirements for wrought titanium-13niobium-1 3zirconium alloy (UNS R58130) bars and wires to be used in the manufacture of surgical implants. The mill products may be supplied as specified by the purchaser with a descaled or pickled, abrasive blasted, chemically milled, ground, machined, peeled, or polished finish. Materials shall be furnished in the unannealed, solution-treated, or capability-aged condition. The mechanical properties to which the alloys shall conform are tensile strength, yield strength, elongation, and reduction of area.
Request a Quote
Description
This specification covers the chemical, mechanical, and metallurgical requirements for wrought titanium-13niobium-1 3zirconium alloy (UNS R58130) bars and wires to be used in the manufacture of surgical implants. The mill products may be supplied as specified by the purchaser with a descaled or pickled, abrasive blasted, chemically milled, ground, machined, peeled, or polished finish. Materials shall be furnished in the unannealed, solution-treated, or capability-aged condition. The mechanical properties to which the alloys shall conform are tensile strength, yield strength, elongation, and reduction of area.
Request a Quote

Suppliers

Company
Product
Description
Supplier Links
Standard Specification for Wrought Titanium-13Niobium-13Zirconium Alloy for Surgical Implant Applications (UNS R58130) - ASTM F1713-08(2013) - ASTM International
West Conshohocken, PA, United States
Standard Specification for Wrought Titanium-13Niobium-13Zirconium Alloy for Surgical Implant Applications (UNS R58130)
ASTM F1713-08(2013)
Standard Specification for Wrought Titanium-13Niobium-13Zirconium Alloy for Surgical Implant Applications (UNS R58130) ASTM F1713-08(2013)
This specification covers the chemical, mechanical, and metallurgical requirements for wrought titanium-13niobium-1 3zirconium alloy (UNS R58130) bars and wires to be used in the manufacture of surgical implants. The mill products may be supplied as specified by the purchaser with a descaled or pickled, abrasive blasted, chemically milled, ground, machined, peeled, or polished finish. Materials shall be furnished in the unannealed, solution-treated, or capability-aged condition. The mechanical properties to which the alloys shall conform are tensile strength, yield strength, elongation, and reduction of area.

This specification covers the chemical, mechanical, and metallurgical requirements for wrought titanium-13niobium-13zirconium alloy (UNS R58130) bars and wires to be used in the manufacture of surgical implants. The mill products may be supplied as specified by the purchaser with a descaled or pickled, abrasive blasted, chemically milled, ground, machined, peeled, or polished finish. Materials shall be furnished in the unannealed, solution-treated, or capability-aged condition. The mechanical properties to which the alloys shall conform are tensile strength, yield strength, elongation, and reduction of area.

Supplier's Site

Technical Specifications

  ASTM International
Product Category Standards and Technical Documents
Product Number ASTM F1713-08(2013)
Product Name Standard Specification for Wrought Titanium-13Niobium-13Zirconium Alloy for Surgical Implant Applications (UNS R58130)
Unlock Full Specs
to access all available technical data

Similar Products