ASTM International Standard Specification for Articulating Total Wrist Implants ASTM F1357-23

Description
This specification covers total wrist implants that provide articulation function through radial carpal components. However, this specification does not include implants with ceramic coated or porous coated surfaces, one-piece elastomeric implants, and those used for custom applications. Implants covered by this specification are of the constrained, partially constrained, or unconstrained joint prosthesis type. The implants shall be manufactured from biocompatible materials made of unalloyed titanium, cobalt-28chromium-6m olybdenum alloy, wrought cobalt-20chromium-15 tungsten-10nickel alloy, wrought titanium-6aluminum-4 vanadium extra low interstitial alloy, wrought 35cobalt-35nickel-20 chromium-10molybdenu m alloy, wrought cobalt-20nickel-20ch romium-3.5molybdenum -3.5tungsten-5iron alloy, cobalt-28chromium-6m olybdenum alloy, titanium-6aluminum-4 vanadium alloy, or wrought cobalt-28chromium-6m olybdenum alloy with dimensions in conformity to the requirements specified. Tests for polymeric creep (cold flow), wear, and range of motion of the device as well as in vitro laboratory testing shall be performed and shall conform to the requirements specified. Per service requirement, metallic implants shall undergo fluorescent penetrant inspection, while cast metallic implants shall undergo radiography.
Request a Quote
Description
This specification covers total wrist implants that provide articulation function through radial carpal components. However, this specification does not include implants with ceramic coated or porous coated surfaces, one-piece elastomeric implants, and those used for custom applications. Implants covered by this specification are of the constrained, partially constrained, or unconstrained joint prosthesis type. The implants shall be manufactured from biocompatible materials made of unalloyed titanium, cobalt-28chromium-6m olybdenum alloy, wrought cobalt-20chromium-15 tungsten-10nickel alloy, wrought titanium-6aluminum-4 vanadium extra low interstitial alloy, wrought 35cobalt-35nickel-20 chromium-10molybdenu m alloy, wrought cobalt-20nickel-20ch romium-3.5molybdenum -3.5tungsten-5iron alloy, cobalt-28chromium-6m olybdenum alloy, titanium-6aluminum-4 vanadium alloy, or wrought cobalt-28chromium-6m olybdenum alloy with dimensions in conformity to the requirements specified. Tests for polymeric creep (cold flow), wear, and range of motion of the device as well as in vitro laboratory testing shall be performed and shall conform to the requirements specified. Per service requirement, metallic implants shall undergo fluorescent penetrant inspection, while cast metallic implants shall undergo radiography.
Request a Quote

Suppliers

Company
Product
Description
Supplier Links
Standard Specification for Articulating Total Wrist Implants - ASTM F1357-23 - ASTM International
West Conshohocken, PA, United States
Standard Specification for Articulating Total Wrist Implants
ASTM F1357-23
Standard Specification for Articulating Total Wrist Implants ASTM F1357-23
This specification covers total wrist implants that provide articulation function through radial carpal components. However, this specification does not include implants with ceramic coated or porous coated surfaces, one-piece elastomeric implants, and those used for custom applications. Implants covered by this specification are of the constrained, partially constrained, or unconstrained joint prosthesis type. The implants shall be manufactured from biocompatible materials made of unalloyed titanium, cobalt-28chromium-6m olybdenum alloy, wrought cobalt-20chromium-15 tungsten-10nickel alloy, wrought titanium-6aluminum-4 vanadium extra low interstitial alloy, wrought 35cobalt-35nickel-20 chromium-10molybdenu m alloy, wrought cobalt-20nickel-20ch romium-3.5molybdenum -3.5tungsten-5iron alloy, cobalt-28chromium-6m olybdenum alloy, titanium-6aluminum-4 vanadium alloy, or wrought cobalt-28chromium-6m olybdenum alloy with dimensions in conformity to the requirements specified. Tests for polymeric creep (cold flow), wear, and range of motion of the device as well as in vitro laboratory testing shall be performed and shall conform to the requirements specified. Per service requirement, metallic implants shall undergo fluorescent penetrant inspection, while cast metallic implants shall undergo radiography.

This specification covers total wrist implants that provide articulation function through radial carpal components. However, this specification does not include implants with ceramic coated or porous coated surfaces, one-piece elastomeric implants, and those used for custom applications. Implants covered by this specification are of the constrained, partially constrained, or unconstrained joint prosthesis type. The implants shall be manufactured from biocompatible materials made of unalloyed titanium, cobalt-28chromium-6molybdenum alloy, wrought cobalt-20chromium-15tungsten-10nickel alloy, wrought titanium-6aluminum-4vanadium extra low interstitial alloy, wrought 35cobalt-35nickel-20chromium-10molybdenum alloy, wrought cobalt-20nickel-20chromium-3.5molybdenum-3.5tungsten-5iron alloy, cobalt-28chromium-6molybdenum alloy, titanium-6aluminum-4vanadium alloy, or wrought cobalt-28chromium-6molybdenum alloy with dimensions in conformity to the requirements specified. Tests for polymeric creep (cold flow), wear, and range of motion of the device as well as in vitro laboratory testing shall be performed and shall conform to the requirements specified. Per service requirement, metallic implants shall undergo fluorescent penetrant inspection, while cast metallic implants shall undergo radiography.

Supplier's Site

Technical Specifications

  ASTM International
Product Category Standards and Technical Documents
Product Number ASTM F1357-23
Product Name Standard Specification for Articulating Total Wrist Implants
Unlock Full Specs
to access all available technical data

Similar Products