ASTM International Practice for Using Absorbed Dose Versus Depth in Materials to Verify the X-ray Output of Flash X-ray Machines (Withdrawn 2000) ASTM E665-94

Description
1.1 This practice covers a procedure for determining absorbed dose versus depth in materials exposed to the X-ray output of flash X-ray machines. It is applicable to all machines whose photon energy spectra have maximum energies ranging from 100 keV to 20 MeV. The determination provides information related to the photon spectrum from the flash X-ray machine. Specifically this measurement can be used for verifying expected X-ray spectra obtained from machine diagnostics and radiation transport calculations and for determining the appropriate equilibrator thickness to be used for dosimetric measurements. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Request a Quote
Description
1.1 This practice covers a procedure for determining absorbed dose versus depth in materials exposed to the X-ray output of flash X-ray machines. It is applicable to all machines whose photon energy spectra have maximum energies ranging from 100 keV to 20 MeV. The determination provides information related to the photon spectrum from the flash X-ray machine. Specifically this measurement can be used for verifying expected X-ray spectra obtained from machine diagnostics and radiation transport calculations and for determining the appropriate equilibrator thickness to be used for dosimetric measurements. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Request a Quote

Suppliers

Company
Product
Description
Supplier Links
Practice for Using Absorbed Dose Versus Depth in Materials to Verify the X-ray Output of Flash X-ray Machines (Withdrawn 2000) - ASTM E665-94 - ASTM International
West Conshohocken, PA, United States
Practice for Using Absorbed Dose Versus Depth in Materials to Verify the X-ray Output of Flash X-ray Machines (Withdrawn 2000)
ASTM E665-94
Practice for Using Absorbed Dose Versus Depth in Materials to Verify the X-ray Output of Flash X-ray Machines (Withdrawn 2000) ASTM E665-94
1.1 This practice covers a procedure for determining absorbed dose versus depth in materials exposed to the X-ray output of flash X-ray machines. It is applicable to all machines whose photon energy spectra have maximum energies ranging from 100 keV to 20 MeV. The determination provides information related to the photon spectrum from the flash X-ray machine. Specifically this measurement can be used for verifying expected X-ray spectra obtained from machine diagnostics and radiation transport calculations and for determining the appropriate equilibrator thickness to be used for dosimetric measurements. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

1.1 This practice covers a procedure for determining absorbed dose versus depth in materials exposed to the X-ray output of flash X-ray machines. It is applicable to all machines whose photon energy spectra have maximum energies ranging from 100 keV to 20 MeV. The determination provides information related to the photon spectrum from the flash X-ray machine. Specifically this measurement can be used for verifying expected X-ray spectra obtained from machine diagnostics and radiation transport calculations and for determining the appropriate equilibrator thickness to be used for dosimetric measurements.

1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Supplier's Site