ASTM International Standard Test Method for Sensory Analysis-Tetrad Test ASTM E3009-15

Description
1.1 This test method covers a procedure for determining whether a perceptible sensory difference exists between samples of two products or to estimate the magnitude of the perceptible difference. 1.2 This test method applies whether a difference may exist in a single sensory attribute or in several. 1.3 This test method is applicable when the nature of the difference between the samples is unknown. The attribute(s) responsible for the difference are not identified. 1.4 The tetrad test is more efficient statistically than the triangle test (Test Method E1885) or the duo-trio test (Test Method E2610). 1.5 The tetrad method involves the evaluation of four samples. When the products being tested cause excessive sensory fatigue, carryover, or adaptation, methods that involve the evaluation of fewer samples (same-different, triangle test, etc.) may be preferred. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Request a Quote
Description
1.1 This test method covers a procedure for determining whether a perceptible sensory difference exists between samples of two products or to estimate the magnitude of the perceptible difference. 1.2 This test method applies whether a difference may exist in a single sensory attribute or in several. 1.3 This test method is applicable when the nature of the difference between the samples is unknown. The attribute(s) responsible for the difference are not identified. 1.4 The tetrad test is more efficient statistically than the triangle test (Test Method E1885) or the duo-trio test (Test Method E2610). 1.5 The tetrad method involves the evaluation of four samples. When the products being tested cause excessive sensory fatigue, carryover, or adaptation, methods that involve the evaluation of fewer samples (same-different, triangle test, etc.) may be preferred. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Request a Quote

Suppliers

Company
Product
Description
Supplier Links
Standard Test Method for Sensory Analysis-Tetrad Test - ASTM E3009-15 - ASTM International
West Conshohocken, PA, United States
Standard Test Method for Sensory Analysis-Tetrad Test
ASTM E3009-15
Standard Test Method for Sensory Analysis-Tetrad Test ASTM E3009-15
1.1 This test method covers a procedure for determining whether a perceptible sensory difference exists between samples of two products or to estimate the magnitude of the perceptible difference. 1.2 This test method applies whether a difference may exist in a single sensory attribute or in several. 1.3 This test method is applicable when the nature of the difference between the samples is unknown. The attribute(s) responsible for the difference are not identified. 1.4 The tetrad test is more efficient statistically than the triangle test (Test Method E1885) or the duo-trio test (Test Method E2610). 1.5 The tetrad method involves the evaluation of four samples. When the products being tested cause excessive sensory fatigue, carryover, or adaptation, methods that involve the evaluation of fewer samples (same-different, triangle test, etc.) may be preferred. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

1.1 This test method covers a procedure for determining whether a perceptible sensory difference exists between samples of two products or to estimate the magnitude of the perceptible difference.


1.2 This test method applies whether a difference may exist in a single sensory attribute or in several.


1.3 This test method is applicable when the nature of the difference between the samples is unknown. The attribute(s) responsible for the difference are not identified.


1.4 The tetrad test is more efficient statistically than the triangle test (Test Method E1885) or the duo-trio test (Test Method E2610).


1.5 The tetrad method involves the evaluation of four samples. When the products being tested cause excessive sensory fatigue, carryover, or adaptation, methods that involve the evaluation of fewer samples (same-different, triangle test, etc.) may be preferred.


1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Supplier's Site

Technical Specifications

  ASTM International
Product Category Standards and Technical Documents
Product Number ASTM E3009-15
Product Name Standard Test Method for Sensory Analysis-Tetrad Test
Unlock Full Specs
to access all available technical data

Similar Products