ASTM International Standard Specification for Portable Air Heaters Used at Personnel Decontamination Stations and Shelters ASTM E2543-08

Description
This specification is used to standardize the portable air heaters used on personnel decontamination lines to insure the heaters provide sufficient heated air for personnel comfort before, during, and after the decontamination for as long as they are needed during the emergency. The heater materials of construction shall be easily cleaned of surface mud and grime with no degradation of the unit's ability to perform its function. The preferred fuels for the heater section of the portable air heater are diesel fuel, gasoline, or bottled propane gas. Measurement of the air heater unit's air flow and input and output temperatures shall be performed.
Request a Quote
Description
This specification is used to standardize the portable air heaters used on personnel decontamination lines to insure the heaters provide sufficient heated air for personnel comfort before, during, and after the decontamination for as long as they are needed during the emergency. The heater materials of construction shall be easily cleaned of surface mud and grime with no degradation of the unit's ability to perform its function. The preferred fuels for the heater section of the portable air heater are diesel fuel, gasoline, or bottled propane gas. Measurement of the air heater unit's air flow and input and output temperatures shall be performed.
Request a Quote

Suppliers

Company
Product
Description
Supplier Links
Standard Specification for Portable Air Heaters Used at Personnel Decontamination Stations and Shelters - ASTM E2543-08 - ASTM International
West Conshohocken, PA, United States
Standard Specification for Portable Air Heaters Used at Personnel Decontamination Stations and Shelters
ASTM E2543-08
Standard Specification for Portable Air Heaters Used at Personnel Decontamination Stations and Shelters ASTM E2543-08
This specification is used to standardize the portable air heaters used on personnel decontamination lines to insure the heaters provide sufficient heated air for personnel comfort before, during, and after the decontamination for as long as they are needed during the emergency. The heater materials of construction shall be easily cleaned of surface mud and grime with no degradation of the unit's ability to perform its function. The preferred fuels for the heater section of the portable air heater are diesel fuel, gasoline, or bottled propane gas. Measurement of the air heater unit's air flow and input and output temperatures shall be performed.

This specification is used to standardize the portable air heaters used on personnel decontamination lines to insure the heaters provide sufficient heated air for personnel comfort before, during, and after the decontamination for as long as they are needed during the emergency. The heater materials of construction shall be easily cleaned of surface mud and grime with no degradation of the unit's ability to perform its function. The preferred fuels for the heater section of the portable air heater are diesel fuel, gasoline, or bottled propane gas. Measurement of the air heater unit's air flow and input and output temperatures shall be performed.

Supplier's Site

Technical Specifications

  ASTM International
Product Category Standards and Technical Documents
Product Number ASTM E2543-08
Product Name Standard Specification for Portable Air Heaters Used at Personnel Decontamination Stations and Shelters
Unlock Full Specs
to access all available technical data

Similar Products