ASTM International Standard Practice for Ion Chromatography Terms and Relationships ASTM E1151-93(2026)

Description
This practice deals primarily with identifying the terms and relationships of those techniques that use ion exchange chromatography to separate mixtures and a conductivity detector to detect the separated components. However, most of the terms should also apply to ion chromatographic techniques that employ other separation and detection mechanisms. The apparatus to be used in the chromatography shall consist of syringe pumps, reciprocating pumps, pneumatic pumps, septum injectors, valve injectors, precolumns, concentrator columns, guard columns, separating columns, suppressor columns, conductivity suppressors, membrane suppressors, micromembrane suppressor, bulk property detectors, and solute property detectors. Chemical reagents to be used in the chemical analysis shall be of four kinds: mobile phase, stationary phase, solid support, and column packing materials. The stationary phase has two types which are the liquid phase and interactive solid phase material. Totally porous packing and pellicular packing are the two types of column packing materials.
Request a Quote
Description
This practice deals primarily with identifying the terms and relationships of those techniques that use ion exchange chromatography to separate mixtures and a conductivity detector to detect the separated components. However, most of the terms should also apply to ion chromatographic techniques that employ other separation and detection mechanisms. The apparatus to be used in the chromatography shall consist of syringe pumps, reciprocating pumps, pneumatic pumps, septum injectors, valve injectors, precolumns, concentrator columns, guard columns, separating columns, suppressor columns, conductivity suppressors, membrane suppressors, micromembrane suppressor, bulk property detectors, and solute property detectors. Chemical reagents to be used in the chemical analysis shall be of four kinds: mobile phase, stationary phase, solid support, and column packing materials. The stationary phase has two types which are the liquid phase and interactive solid phase material. Totally porous packing and pellicular packing are the two types of column packing materials.
Request a Quote

Suppliers

Company
Product
Description
Supplier Links
Standard Practice for Ion Chromatography Terms and Relationships - ASTM E1151-93(2026) - ASTM International
West Conshohocken, PA, United States
Standard Practice for Ion Chromatography Terms and Relationships
ASTM E1151-93(2026)
Standard Practice for Ion Chromatography Terms and Relationships ASTM E1151-93(2026)
This practice deals primarily with identifying the terms and relationships of those techniques that use ion exchange chromatography to separate mixtures and a conductivity detector to detect the separated components. However, most of the terms should also apply to ion chromatographic techniques that employ other separation and detection mechanisms. The apparatus to be used in the chromatography shall consist of syringe pumps, reciprocating pumps, pneumatic pumps, septum injectors, valve injectors, precolumns, concentrator columns, guard columns, separating columns, suppressor columns, conductivity suppressors, membrane suppressors, micromembrane suppressor, bulk property detectors, and solute property detectors. Chemical reagents to be used in the chemical analysis shall be of four kinds: mobile phase, stationary phase, solid support, and column packing materials. The stationary phase has two types which are the liquid phase and interactive solid phase material. Totally porous packing and pellicular packing are the two types of column packing materials.

This practice deals primarily with identifying the terms and relationships of those techniques that use ion exchange chromatography to separate mixtures and a conductivity detector to detect the separated components. However, most of the terms should also apply to ion chromatographic techniques that employ other separation and detection mechanisms. The apparatus to be used in the chromatography shall consist of syringe pumps, reciprocating pumps, pneumatic pumps, septum injectors, valve injectors, precolumns, concentrator columns, guard columns, separating columns, suppressor columns, conductivity suppressors, membrane suppressors, micromembrane suppressor, bulk property detectors, and solute property detectors. Chemical reagents to be used in the chemical analysis shall be of four kinds: mobile phase, stationary phase, solid support, and column packing materials. The stationary phase has two types which are the liquid phase and interactive solid phase material. Totally porous packing and pellicular packing are the two types of column packing materials.

Supplier's Site

Technical Specifications

  ASTM International
Product Category Standards and Technical Documents
Product Number ASTM E1151-93(2026)
Product Name Standard Practice for Ion Chromatography Terms and Relationships
Unlock Full Specs
to access all available technical data

Similar Products