ASTM International Test Method for Benzene, Toluene, Xylene, (BTX) Concentrates Analysis by Capillary Column Gas Chromatography ASTM D6563-00

Description
1.1 This test method covers the determination of the total nonaromatic hydrocarbons, benzene, toluene, ethylbenzene, xylenes, and C9 + aromatic hydrocarbons in BTX concentrates by capillary column gas chromatography. This test method is applicable ot materials with a final boiling point below 215oC. Individual components can be determined fro 0.01 to 90%. 1.3 The following applies to all specified limits in this standard; for purpose of determining conformance with this standard, an observed value or a calculated value shall be rounded off "to the nearest unit" in the right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E29. 1.4 This standard does not purport to address all of the safety concerns, if any, asociated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific precautionary statement, see Section 9.
Request a Quote
Description
1.1 This test method covers the determination of the total nonaromatic hydrocarbons, benzene, toluene, ethylbenzene, xylenes, and C9 + aromatic hydrocarbons in BTX concentrates by capillary column gas chromatography. This test method is applicable ot materials with a final boiling point below 215oC. Individual components can be determined fro 0.01 to 90%. 1.3 The following applies to all specified limits in this standard; for purpose of determining conformance with this standard, an observed value or a calculated value shall be rounded off "to the nearest unit" in the right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E29. 1.4 This standard does not purport to address all of the safety concerns, if any, asociated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific precautionary statement, see Section 9.
Request a Quote

Suppliers

Company
Product
Description
Supplier Links
Test Method for Benzene, Toluene, Xylene, (BTX) Concentrates Analysis by Capillary Column Gas Chromatography - ASTM D6563-00 - ASTM International
West Conshohocken, PA, United States
Test Method for Benzene, Toluene, Xylene, (BTX) Concentrates Analysis by Capillary Column Gas Chromatography
ASTM D6563-00
Test Method for Benzene, Toluene, Xylene, (BTX) Concentrates Analysis by Capillary Column Gas Chromatography ASTM D6563-00
1.1 This test method covers the determination of the total nonaromatic hydrocarbons, benzene, toluene, ethylbenzene, xylenes, and C9 + aromatic hydrocarbons in BTX concentrates by capillary column gas chromatography. This test method is applicable ot materials with a final boiling point below 215oC. Individual components can be determined fro 0.01 to 90%. 1.3 The following applies to all specified limits in this standard; for purpose of determining conformance with this standard, an observed value or a calculated value shall be rounded off "to the nearest unit" in the right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E29. 1.4 This standard does not purport to address all of the safety concerns, if any, asociated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific precautionary statement, see Section 9.

1.1 This test method covers the determination of the total nonaromatic hydrocarbons, benzene, toluene, ethylbenzene, xylenes, and C9 + aromatic hydrocarbons in BTX concentrates by capillary column gas chromatography. This test method is applicable ot materials with a final boiling point below 215oC.

Individual components can be determined fro 0.01 to 90%.

1.3 The following applies to all specified limits in this standard; for purpose of determining conformance with this standard, an observed value or a calculated value shall be rounded off "to the nearest unit" in the right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E29.

1.4 This standard does not purport to address all of the safety concerns, if any, asociated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific precautionary statement, see Section 9.

Supplier's Site

Technical Specifications

  ASTM International
Product Category Standards and Technical Documents
Product Number ASTM D6563-00
Product Name Test Method for Benzene, Toluene, Xylene, (BTX) Concentrates Analysis by Capillary Column Gas Chromatography
Unlock Full Specs
to access all available technical data

Similar Products