ASTM International Standard Test Method for Oxidation-Reduction Potential of Water ASTM D1498-14

Description
This test method covers the apparatus and procedure for the electrometric measurement of oxidation-reduction potential (ORP) in water. The test method described has been designed for the routine and process measurement of oxidation-reduction potential. ORP is defined as the electromotive force between a noble metal electrode and a reference electrode when immersed in a solution.� The ORP electrodes are inert and measure the ratio of the activities of the oxidized to the reduced species present. In addition, the ORP electrodes reliably measure ORP in nearly all aqueous solutions and in general are not subject to solution interference from color, turbidity, colloidal matter, and suspended matter. The apparatus to be used in the measurement of ORP includes: pH meter, reference electrode, oxidation-reduction electrode and electrode assembly. Materials necessary in the procedure for ORP measurement include chemical reagents, aqua regia, water, buffer standard salts, phthalate reference buffer solution, phosphate reference buffer solution, chromic acid cleaning solution, detergent, nitric acid, redox standard solution or ferrous-ferric reference solution, and redox reference quinhydrone solutions.
Request a Quote
Description
This test method covers the apparatus and procedure for the electrometric measurement of oxidation-reduction potential (ORP) in water. The test method described has been designed for the routine and process measurement of oxidation-reduction potential. ORP is defined as the electromotive force between a noble metal electrode and a reference electrode when immersed in a solution.� The ORP electrodes are inert and measure the ratio of the activities of the oxidized to the reduced species present. In addition, the ORP electrodes reliably measure ORP in nearly all aqueous solutions and in general are not subject to solution interference from color, turbidity, colloidal matter, and suspended matter. The apparatus to be used in the measurement of ORP includes: pH meter, reference electrode, oxidation-reduction electrode and electrode assembly. Materials necessary in the procedure for ORP measurement include chemical reagents, aqua regia, water, buffer standard salts, phthalate reference buffer solution, phosphate reference buffer solution, chromic acid cleaning solution, detergent, nitric acid, redox standard solution or ferrous-ferric reference solution, and redox reference quinhydrone solutions.
Request a Quote

Suppliers

Company
Product
Description
Supplier Links
Standard Test Method for Oxidation-Reduction Potential of Water - ASTM D1498-14 - ASTM International
West Conshohocken, PA, United States
Standard Test Method for Oxidation-Reduction Potential of Water
ASTM D1498-14
Standard Test Method for Oxidation-Reduction Potential of Water ASTM D1498-14
This test method covers the apparatus and procedure for the electrometric measurement of oxidation-reduction potential (ORP) in water. The test method described has been designed for the routine and process measurement of oxidation-reduction potential. ORP is defined as the electromotive force between a noble metal electrode and a reference electrode when immersed in a solution.� The ORP electrodes are inert and measure the ratio of the activities of the oxidized to the reduced species present. In addition, the ORP electrodes reliably measure ORP in nearly all aqueous solutions and in general are not subject to solution interference from color, turbidity, colloidal matter, and suspended matter. The apparatus to be used in the measurement of ORP includes: pH meter, reference electrode, oxidation-reduction electrode and electrode assembly. Materials necessary in the procedure for ORP measurement include chemical reagents, aqua regia, water, buffer standard salts, phthalate reference buffer solution, phosphate reference buffer solution, chromic acid cleaning solution, detergent, nitric acid, redox standard solution or ferrous-ferric reference solution, and redox reference quinhydrone solutions.

This test method covers the apparatus and procedure for the electrometric measurement of oxidation-reduction potential (ORP) in water. The test method described has been designed for the routine and process measurement of oxidation-reduction potential. ORP is defined as the electromotive force between a noble metal electrode and a reference electrode when immersed in a solution.� The ORP electrodes are inert and measure the ratio of the activities of the oxidized to the reduced species present. In addition, the ORP electrodes reliably measure ORP in nearly all aqueous solutions and in general are not subject to solution interference from color, turbidity, colloidal matter, and suspended matter. The apparatus to be used in the measurement of ORP includes: pH meter, reference electrode, oxidation-reduction electrode and electrode assembly. Materials necessary in the procedure for ORP measurement include chemical reagents, aqua regia, water, buffer standard salts, phthalate reference buffer solution, phosphate reference buffer solution, chromic acid cleaning solution, detergent, nitric acid, redox standard solution or ferrous-ferric reference solution, and redox reference quinhydrone solutions.

Supplier's Site

Technical Specifications

  ASTM International
Product Category Standards and Technical Documents
Product Number ASTM D1498-14
Product Name Standard Test Method for Oxidation-Reduction Potential of Water
Unlock Full Specs
to access all available technical data

Similar Products