This specification covers acceptance testing of rubber insulating covers for use as portable protective devices for protection of workers from accidental contact with live electrical conductors, apparatus, or circuits. It includes insulator hoods, dead-end protectors, line hose connectors, cable end covers, and miscellaneous covers. The electrical, physical, and chemical requirements of this specification shall apply also to any new or modified styles of covers that may be developed for specific purposes. The covers shall be of three types: Type I - non-resistant to ozone, made from a high-grade cis-1,4-polyisoprene rubber compound of natural or synthetic origin, properly vulcanized; Type II - ozone resistant, made of any elastomer or combination of elastomeric compounds; and Type III - ozone-resistant, made of any combination of elastomer and thermoplastic polymer, elastic in nature. Electrical proof, ozone resistance, chemical, and physical tests shall be conducted on each of the covers to determine its acceptability. The cover material shall conform to the tensile strength requirements, the accelerated aging, and for Type I covers, the determination of rubber polymer. Each cover shall withstand the specified ac proof-test voltage (rms value) or the dc proof-test voltage (average value).
Request a Quote
Description
This specification covers acceptance testing of rubber insulating covers for use as portable protective devices for protection of workers from accidental contact with live electrical conductors, apparatus, or circuits. It includes insulator hoods, dead-end protectors, line hose connectors, cable end covers, and miscellaneous covers. The electrical, physical, and chemical requirements of this specification shall apply also to any new or modified styles of covers that may be developed for specific purposes. The covers shall be of three types: Type I - non-resistant to ozone, made from a high-grade cis-1,4-polyisoprene rubber compound of natural or synthetic origin, properly vulcanized; Type II - ozone resistant, made of any elastomer or combination of elastomeric compounds; and Type III - ozone-resistant, made of any combination of elastomer and thermoplastic polymer, elastic in nature. Electrical proof, ozone resistance, chemical, and physical tests shall be conducted on each of the covers to determine its acceptability. The cover material shall conform to the tensile strength requirements, the accelerated aging, and for Type I covers, the determination of rubber polymer. Each cover shall withstand the specified ac proof-test voltage (rms value) or the dc proof-test voltage (average value).
Request a Quote

Suppliers

Company
Product
Description
Supplier Links
Standard Specification for Rubber Insulating Covers - ASTM D1049-98(2022) - ASTM International
West Conshohocken, PA, United States
Standard Specification for Rubber Insulating Covers
ASTM D1049-98(2022)
Standard Specification for Rubber Insulating Covers ASTM D1049-98(2022)
This specification covers acceptance testing of rubber insulating covers for use as portable protective devices for protection of workers from accidental contact with live electrical conductors, apparatus, or circuits. It includes insulator hoods, dead-end protectors, line hose connectors, cable end covers, and miscellaneous covers. The electrical, physical, and chemical requirements of this specification shall apply also to any new or modified styles of covers that may be developed for specific purposes. The covers shall be of three types: Type I - non-resistant to ozone, made from a high-grade cis-1,4-polyisoprene rubber compound of natural or synthetic origin, properly vulcanized; Type II - ozone resistant, made of any elastomer or combination of elastomeric compounds; and Type III - ozone-resistant, made of any combination of elastomer and thermoplastic polymer, elastic in nature. Electrical proof, ozone resistance, chemical, and physical tests shall be conducted on each of the covers to determine its acceptability. The cover material shall conform to the tensile strength requirements, the accelerated aging, and for Type I covers, the determination of rubber polymer. Each cover shall withstand the specified ac proof-test voltage (rms value) or the dc proof-test voltage (average value).

This specification covers acceptance testing of rubber insulating covers for use as portable protective devices for protection of workers from accidental contact with live electrical conductors, apparatus, or circuits. It includes insulator hoods, dead-end protectors, line hose connectors, cable end covers, and miscellaneous covers. The electrical, physical, and chemical requirements of this specification shall apply also to any new or modified styles of covers that may be developed for specific purposes. The covers shall be of three types: Type I - non-resistant to ozone, made from a high-grade cis-1,4-polyisoprene rubber compound of natural or synthetic origin, properly vulcanized; Type II - ozone resistant, made of any elastomer or combination of elastomeric compounds; and Type III - ozone-resistant, made of any combination of elastomer and thermoplastic polymer, elastic in nature. Electrical proof, ozone resistance, chemical, and physical tests shall be conducted on each of the covers to determine its acceptability. The cover material shall conform to the tensile strength requirements, the accelerated aging, and for Type I covers, the determination of rubber polymer. Each cover shall withstand the specified ac proof-test voltage (rms value) or the dc proof-test voltage (average value).

Supplier's Site

Technical Specifications

  ASTM International
Product Category Standards and Technical Documents
Product Number ASTM D1049-98(2022)
Product Name Standard Specification for Rubber Insulating Covers
Unlock Full Specs
to access all available technical data

Similar Products