This specification covers reinforced concrete culvert, storm drain, and sewer pipe. The pipe manufactured with this specification shall be of five classes: Class I, Class II, Class III, Class IV, and Class V. The strength requirements for each class are specified. The reinforced concrete shall consists of: cementitious materials, mineral aggregates, and water. Cementitious materials are the following: cement, ground granulated blast-furnace slag, fly ash, and allowable combinations of cementitious materials. Other materials include: admixtures and blends, steel reinforcement, and synthetic fibers. Design tables and modified of special designs are given. Reinforcements are the following: circumferential reinforcement, longitudinal reinforcement, and joint reinforcement for rubber and non-rubber gasket joints. The physical properties shall conform to the required test for external load crushing strength. The following concrete tests shall be done: compression testing of cylinders, compression testing of cores, absorption test, and equipment test.
Request a Quote
Description
This specification covers reinforced concrete culvert, storm drain, and sewer pipe. The pipe manufactured with this specification shall be of five classes: Class I, Class II, Class III, Class IV, and Class V. The strength requirements for each class are specified. The reinforced concrete shall consists of: cementitious materials, mineral aggregates, and water. Cementitious materials are the following: cement, ground granulated blast-furnace slag, fly ash, and allowable combinations of cementitious materials. Other materials include: admixtures and blends, steel reinforcement, and synthetic fibers. Design tables and modified of special designs are given. Reinforcements are the following: circumferential reinforcement, longitudinal reinforcement, and joint reinforcement for rubber and non-rubber gasket joints. The physical properties shall conform to the required test for external load crushing strength. The following concrete tests shall be done: compression testing of cylinders, compression testing of cores, absorption test, and equipment test.
Request a Quote

Suppliers

Company
Product
Description
Supplier Links
Standard Specification for Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe - ASTM C76-13 - ASTM International
West Conshohocken, PA, United States
Standard Specification for Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe
ASTM C76-13
Standard Specification for Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe ASTM C76-13
This specification covers reinforced concrete culvert, storm drain, and sewer pipe. The pipe manufactured with this specification shall be of five classes: Class I, Class II, Class III, Class IV, and Class V. The strength requirements for each class are specified. The reinforced concrete shall consists of: cementitious materials, mineral aggregates, and water. Cementitious materials are the following: cement, ground granulated blast-furnace slag, fly ash, and allowable combinations of cementitious materials. Other materials include: admixtures and blends, steel reinforcement, and synthetic fibers. Design tables and modified of special designs are given. Reinforcements are the following: circumferential reinforcement, longitudinal reinforcement, and joint reinforcement for rubber and non-rubber gasket joints. The physical properties shall conform to the required test for external load crushing strength. The following concrete tests shall be done: compression testing of cylinders, compression testing of cores, absorption test, and equipment test.

This specification covers reinforced concrete culvert, storm drain, and sewer pipe. The pipe manufactured with this specification shall be of five classes: Class I, Class II, Class III, Class IV, and Class V. The strength requirements for each class are specified. The reinforced concrete shall consists of: cementitious materials, mineral aggregates, and water. Cementitious materials are the following: cement, ground granulated blast-furnace slag, fly ash, and allowable combinations of cementitious materials. Other materials include: admixtures and blends, steel reinforcement, and synthetic fibers. Design tables and modified of special designs are given. Reinforcements are the following: circumferential reinforcement, longitudinal reinforcement, and joint reinforcement for rubber and non-rubber gasket joints. The physical properties shall conform to the required test for external load crushing strength. The following concrete tests shall be done: compression testing of cylinders, compression testing of cores, absorption test, and equipment test.

Supplier's Site

Technical Specifications

  ASTM International
Product Category Standards and Technical Documents
Product Number ASTM C76-13
Product Name Standard Specification for Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe
Unlock Full Specs
to access all available technical data

Similar Products