The VCA Evaporative Condenser utilizes axial fans to minimize energy consumption. The features designed into the VCA Evaporative Condenser product line address energy efficiency, reliability, maintainability, and field assembly needs of the market. These features provide the end user with a long service life and the contractor with ease of installation and commissioning.
Benefits:
Evaporative condensers minimize the energy consumption of the entire system by providing lower condensing temperatures. Owners save money while conserving natural resources and reducing environmental impact.
InterLok™ System — The coil section self aligns with the basin section. This feature significantly reduces the time required to rig the VCA. Newly designed rigging ears allow for use of a single spreader bar per lift.
Support — All models mount directly on two parallel I-beams and ship complete with motors and drives factory-installed and aligned.
Access Doors — Two 30” x 44” access doors are standard on side blow units and one on end blow units. This allows the interior of the unit to be easily accessed for adjusting the float valve, cleaning the strainer or flushing the basin. A large hinged internal partition door and an external door step are standard on all side blow units.
BranchLok™ Removal System — Water distribution branch removal system that requires no tools.
Powerband Belts — The fans, motor, and drive system are located outside of the moist discharge airstream, protecting them from moisture, condensation and icing. Backed by a 5-year fan drive and motor warranty, these units are suitable for year round operation.
The VCA Evaporative Condenser utilizes axial fans to minimize energy consumption. The features designed into the VCA Evaporative Condenser product line address energy efficiency, reliability, maintainability, and field assembly needs of the market. These features provide the end user with a long service life and the contractor with ease of installation and commissioning.
Benefits:
- Evaporative condensers minimize the energy consumption of the entire system by providing lower condensing temperatures. Owners save money while conserving natural resources and reducing environmental impact.
- InterLok™ System — The coil section self aligns with the basin section. This feature significantly reduces the time required to rig the VCA. Newly designed rigging ears allow for use of a single spreader bar per lift.
- Support — All models mount directly on two parallel I-beams and ship complete with motors and drives factory-installed and aligned.
- Access Doors — Two 30” x 44” access doors are standard on side blow units and one on end blow units. This allows the interior of the unit to be easily accessed for adjusting the float valve, cleaning the strainer or flushing the basin. A large hinged internal partition door and an external door step are standard on all side blow units.
- BranchLok™ Removal System — Water distribution branch removal system that requires no tools.
- Powerband Belts — The fans, motor, and drive system are located outside of the moist discharge airstream, protecting them from moisture, condensation and icing. Backed by a 5-year fan drive and motor warranty, these units are suitable for year round operation.