Restek Rtx®-DHA Columns

Description
Columns meet or exceed all ASTM D6730-01 and CAN/CGSB 3.0 No. 14.3-99 method guidelines; test report for method D6730 supplied with each column. Excellent responses and peak symmetry for polar oxygenates. Gasolines are complex mixtures of hundreds of compounds. Information about concentrations of the individual components is important for evaluating raw materials and for controlling refinery processes. ASTM D6730-01 outlines a high-resolution GC method for detailed hydrocarbon analysis (DHA) of gasolines. Rtx®-DHA columns are ideal for DHA methods and easily meet or exceed both ASTM D6730-01 and Canadian General Standards Board CAN/CGSB 3.0 No. 14.3-99 requirements. Every Rtx®-DHA column is tested for retention, efficiency, stationary phase selectivity, and bleed—guaranteeing reproducible column-to-column performance.
Description
Columns meet or exceed all ASTM D6730-01 and CAN/CGSB 3.0 No. 14.3-99 method guidelines; test report for method D6730 supplied with each column. Excellent responses and peak symmetry for polar oxygenates. Gasolines are complex mixtures of hundreds of compounds. Information about concentrations of the individual components is important for evaluating raw materials and for controlling refinery processes. ASTM D6730-01 outlines a high-resolution GC method for detailed hydrocarbon analysis (DHA) of gasolines. Rtx®-DHA columns are ideal for DHA methods and easily meet or exceed both ASTM D6730-01 and Canadian General Standards Board CAN/CGSB 3.0 No. 14.3-99 requirements. Every Rtx®-DHA column is tested for retention, efficiency, stationary phase selectivity, and bleed—guaranteeing reproducible column-to-column performance.

Suppliers

Company
Product
Description
Supplier Links
Rtx®-DHA Columns -  - Restek
Bellefonte, PA, USA
Rtx®-DHA Columns
Rtx®-DHA Columns
Columns meet or exceed all ASTM D6730-01 and CAN/CGSB 3.0 No. 14.3-99 method guidelines; test report for method D6730 supplied with each column. Excellent responses and peak symmetry for polar oxygenates. Gasolines are complex mixtures of hundreds of compounds. Information about concentrations of the individual components is important for evaluating raw materials and for controlling refinery processes. ASTM D6730-01 outlines a high-resolution GC method for detailed hydrocarbon analysis (DHA) of gasolines. Rtx®-DHA columns are ideal for DHA methods and easily meet or exceed both ASTM D6730-01 and Canadian General Standards Board CAN/CGSB 3.0 No. 14.3-99 requirements. Every Rtx®-DHA column is tested for retention, efficiency, stationary phase selectivity, and bleed—guaranteeing reproducible column-to-column performance.
  • Columns meet or exceed all ASTM D6730-01 and CAN/CGSB 3.0 No. 14.3-99 method guidelines; test report for method D6730 supplied with each column.
  • Excellent responses and peak symmetry for polar oxygenates.

Gasolines are complex mixtures of hundreds of compounds. Information about concentrations of the individual components is important for evaluating raw materials and for controlling refinery processes. ASTM D6730-01 outlines a high-resolution GC method for detailed hydrocarbon analysis (DHA) of gasolines. Rtx®-DHA columns are ideal for DHA methods and easily meet or exceed both ASTM D6730-01 and Canadian General Standards Board CAN/CGSB 3.0 No. 14.3-99 requirements. Every Rtx®-DHA column is tested for retention, efficiency, stationary phase selectivity, and bleed—guaranteeing reproducible column-to-column performance.

Supplier's Site

Technical Specifications

  Restek
Product Category GC Columns
Product Name Rtx®-DHA Columns
Column Type Capillary
Construction Material Silicate Glass; Other; Fused Silica
Column Length 50 to 150 m (164 to 492 ft)
Unlock Full Specs
to access all available technical data

Similar Products

MXT®-1 Columns -  - Restek
Specs
Column Type Capillary
Construction Material Stainless Steel
Column Length 6 to 105 m (19.69 to 344 ft)
View Details
Abel Industries Canada Ltd.
Specs
Column Length 20 m (65.62 ft)
Inner Diameter (ID) 180 µm (7.09 mils)
Film Thickness 0.1800 µm (0.0071 mils)
View Details
Rt®-XLSulfur Columns -  - Restek
Specs
Column Type Packed
Column Length 1 to 2 m (3.28 to 6.56 ft)
Inner Diameter (ID) 2000 to 3200 µm (78.74 to 126 mils)
View Details
Abel Industries Canada Ltd.
Specs
Column Length 30 m (98.43 ft)
Inner Diameter (ID) 530 µm (20.87 mils)
Film Thickness 30 µm (1.18 mils)
View Details