Restek MXT®-200 Columns

Description
(midpolarity phase; Crossbond® trifluoropropylmethy l polysiloxane) General purpose columns for solvents, Freon® fluorocarbons, alcohols, ketones, silanes, and glycols. Excellent confirmation column with an Rtx®-5 column, for phenols, nitrosamines, organochlorine pesticides, chlorinated hydrocarbons, and chlorophenoxy herbicides. Temperature range: -20 °C to 400 °C. Equivalent to USP G6 phase. Similar Phase(s): DB-200, DB-210
Description
(midpolarity phase; Crossbond® trifluoropropylmethy l polysiloxane) General purpose columns for solvents, Freon® fluorocarbons, alcohols, ketones, silanes, and glycols. Excellent confirmation column with an Rtx®-5 column, for phenols, nitrosamines, organochlorine pesticides, chlorinated hydrocarbons, and chlorophenoxy herbicides. Temperature range: -20 °C to 400 °C. Equivalent to USP G6 phase. Similar Phase(s): DB-200, DB-210

Suppliers

Company
Product
Description
Supplier Links
MXT®-200 Columns -  - Restek
Bellefonte, PA, USA
MXT®-200 Columns
MXT®-200 Columns
(midpolarity phase; Crossbond® trifluoropropylmethy l polysiloxane) General purpose columns for solvents, Freon® fluorocarbons, alcohols, ketones, silanes, and glycols. Excellent confirmation column with an Rtx®-5 column, for phenols, nitrosamines, organochlorine pesticides, chlorinated hydrocarbons, and chlorophenoxy herbicides. Temperature range: -20 °C to 400 °C. Equivalent to USP G6 phase. Similar Phase(s): DB-200, DB-210

(midpolarity phase; Crossbond® trifluoropropylmethyl polysiloxane)

  • General purpose columns for solvents, Freon® fluorocarbons, alcohols, ketones, silanes, and glycols. Excellent confirmation column with an Rtx®-5 column, for phenols, nitrosamines, organochlorine pesticides, chlorinated hydrocarbons, and chlorophenoxy herbicides.
  • Temperature range: -20 °C to 400 °C.
  • Equivalent to USP G6 phase.

Similar Phase(s):

DB-200, DB-210

Supplier's Site

Technical Specifications

  Restek
Product Category GC Columns
Product Name MXT®-200 Columns
Column Type Capillary
Construction Material Stainless Steel
Column Length 15 to 60 m (49.21 to 197 ft)
Unlock Full Specs
to access all available technical data

Similar Products

Rtx®-200MS—Low-bleed GC/MS Columns -  - Restek
Specs
Column Type Capillary
Construction Material Silicate Glass; Other; Fused Silica
Column Length 30 m (98.43 ft)
View Details
Abel Industries Canada Ltd.
Specs
Column Length 15 m (49.21 ft)
Inner Diameter (ID) 320 µm (12.6 mils)
Film Thickness 0.2500 µm (0.0098 mils)
View Details
HayeSep®Series Packings -  - Restek
Specs
Column Type Packed
Operating Temperature ? to 554 F (? to 290 C)
View Details
Abel Industries Canada Ltd.
Specs
Column Length 30 m (98.43 ft)
Inner Diameter (ID) 250 µm (9.84 mils)
Film Thickness 0.2500 µm (0.0098 mils)
View Details