METTLER TOLEDO Thermal Analysis Crucible MP 120 uL, SST, 25 pcs, pin 26929

Description
Set of 25 crucibles, lids and seals. The medium pressure crucible is sealed with an FPM O-ring. The maximum pressure is 2 MPa. The crucible can also be sealed without using an O-ring (self-generated atmosphere). Medium-pressure crucible with pin The medium-pressure crucible with pin can only be used for DSC measurements, the pan can also be used without lid. Single use crucible When sealed with a lid and special seal, it is a single use crucible and cannot be regenerated. It withstands a maximum pressure of 2 MPa. Perfect crucible for liquids The medium-pressure crucible is the perfect tool for samples containing liquids such as water, for temperatures above boiling point. Special die/plunger set required In order to seal the crucible, the crucible sealing press must be equipped with a special die set (Art No: 119428). Seal from FPM is included The medium-pressure crucible is sealed with an FPM O-ring. As FPM is slightly permeable to water, this seal is more suitable for other liquids. PCTFE seals for water If water causes an issue, it is recommended that you use PCTFE (Polychlorotrifluoro ethylene) seals, Art. No. 26933. PCTFE, however, shows a DSC melting peak at about 220 °C. Crucible with self-generated atmosphere The crucible can also be used without a seal (sealed with lid only). In this case, a self-generated internal atmosphere will form.
Request a Quote
Description
Set of 25 crucibles, lids and seals. The medium pressure crucible is sealed with an FPM O-ring. The maximum pressure is 2 MPa. The crucible can also be sealed without using an O-ring (self-generated atmosphere). Medium-pressure crucible with pin The medium-pressure crucible with pin can only be used for DSC measurements, the pan can also be used without lid. Single use crucible When sealed with a lid and special seal, it is a single use crucible and cannot be regenerated. It withstands a maximum pressure of 2 MPa. Perfect crucible for liquids The medium-pressure crucible is the perfect tool for samples containing liquids such as water, for temperatures above boiling point. Special die/plunger set required In order to seal the crucible, the crucible sealing press must be equipped with a special die set (Art No: 119428). Seal from FPM is included The medium-pressure crucible is sealed with an FPM O-ring. As FPM is slightly permeable to water, this seal is more suitable for other liquids. PCTFE seals for water If water causes an issue, it is recommended that you use PCTFE (Polychlorotrifluoro ethylene) seals, Art. No. 26933. PCTFE, however, shows a DSC melting peak at about 220 °C. Crucible with self-generated atmosphere The crucible can also be used without a seal (sealed with lid only). In this case, a self-generated internal atmosphere will form.
Request a Quote

Suppliers

Company
Product
Description
Supplier Links
Crucible MP 120 uL, SST, 25 pcs, pin - 26929 - METTLER TOLEDO Thermal Analysis
Greifensee, Switzerland
Crucible MP 120 uL, SST, 25 pcs, pin
26929
Crucible MP 120 uL, SST, 25 pcs, pin 26929
Set of 25 crucibles, lids and seals. The medium pressure crucible is sealed with an FPM O-ring. The maximum pressure is 2 MPa. The crucible can also be sealed without using an O-ring (self-generated atmosphere). Medium-pressure crucible with pin The medium-pressure crucible with pin can only be used for DSC measurements, the pan can also be used without lid. Single use crucible When sealed with a lid and special seal, it is a single use crucible and cannot be regenerated. It withstands a maximum pressure of 2 MPa. Perfect crucible for liquids The medium-pressure crucible is the perfect tool for samples containing liquids such as water, for temperatures above boiling point. Special die/plunger set required In order to seal the crucible, the crucible sealing press must be equipped with a special die set (Art No: 119428). Seal from FPM is included The medium-pressure crucible is sealed with an FPM O-ring. As FPM is slightly permeable to water, this seal is more suitable for other liquids. PCTFE seals for water If water causes an issue, it is recommended that you use PCTFE (Polychlorotrifluoro ethylene) seals, Art. No. 26933. PCTFE, however, shows a DSC melting peak at about 220 °C. Crucible with self-generated atmosphere The crucible can also be used without a seal (sealed with lid only). In this case, a self-generated internal atmosphere will form.

Set of 25 crucibles, lids and seals. The medium pressure crucible is sealed with an FPM O-ring. The maximum pressure is 2 MPa. The crucible can also be sealed without using an O-ring (self-generated atmosphere).

  • Medium-pressure crucible with pin The medium-pressure crucible with pin can only be used for DSC measurements, the pan can also be used without lid.
  • Single use crucible When sealed with a lid and special seal, it is a single use crucible and cannot be regenerated. It withstands a maximum pressure of 2 MPa.
  • Perfect crucible for liquids The medium-pressure crucible is the perfect tool for samples containing liquids such as water, for temperatures above boiling point.
  • Special die/plunger set required In order to seal the crucible, the crucible sealing press must be equipped with a special die set (Art No: 119428).
  • Seal from FPM is included The medium-pressure crucible is sealed with an FPM O-ring. As FPM is slightly permeable to water, this seal is more suitable for other liquids.
  • PCTFE seals for water If water causes an issue, it is recommended that you use PCTFE (Polychlorotrifluoroethylene) seals, Art. No. 26933. PCTFE, however, shows a DSC melting peak at about 220 °C.
  • Crucible with self-generated atmosphere The crucible can also be used without a seal (sealed with lid only). In this case, a self-generated internal atmosphere will form.
Supplier's Site

Technical Specifications

  METTLER TOLEDO Thermal Analysis
Product Category Crucibles
Product Number 26929
Product Name Crucible MP 120 uL, SST, 25 pcs, pin
Crucible Type Cover / Lid
Unlock Full Specs
to access all available technical data

Similar Products

Crucible MP 120 uL, SST, 25 pcs - 29990 - METTLER TOLEDO Thermal Analysis
METTLER TOLEDO Thermal Analysis
Specs
Crucible Type Cover / Lid
Capacity 0 cubic inches (0.0120 cl)
Material Types Metal; Steel/Au
View Details
Crucible HP 25 uL, SST/Au, 25 pcs - 30077139 - METTLER TOLEDO Thermal Analysis
METTLER TOLEDO Thermal Analysis
Specs
Crucible Type Cover / Lid
Bottom / Pour Type FlatBottom
Capacity 0 cubic inches (0.0025 cl)
View Details
Crucible 150 uL, Alox, 20 pcs - 24124 - METTLER TOLEDO Thermal Analysis
METTLER TOLEDO Thermal Analysis
Specs
Crucible Type Cover / Lid
Bottom / Pour Type FlatBottom
Capacity 0 cubic inches (0.0150 cl)
View Details
Burst Disk - 27216 - METTLER TOLEDO Thermal Analysis
METTLER TOLEDO Thermal Analysis
Specs
Material Types Metal; Gold
View Details