Maury Microwave VNA Calibration Standard 8046F6

Description
Fixed flush and fixed offset short circuit terminations (shorts) are used to establish reference planes in transmission systems and as key elements in the calibration of vector network analyzers (VNAs). Offset shorts can be used for banded calibrations of VNA. Those with the longest offset are often used to evaluate the calibration effectiveness of a VNA by measuring the effective source match after calibration.
Request a Quote
Description
Fixed flush and fixed offset short circuit terminations (shorts) are used to establish reference planes in transmission systems and as key elements in the calibration of vector network analyzers (VNAs). Offset shorts can be used for banded calibrations of VNA. Those with the longest offset are often used to evaluate the calibration effectiveness of a VNA by measuring the effective source match after calibration.
Request a Quote
Datasheet
Datasheet Summary
Powered by GS/AI

The 8046F6 is a female 3.5mm connector fixed offset short circuit termination used to establish reference planes and calibrate vector network analyzers. It has a phase accuracy of ±2.0°, a reflection coefficient of 0.98, and an offset length of 0.1970 inches, with a frequency range of DC to 26.5 GHz.

Datasheet Summary
Powered by GS/AI

The 8046F6 is a female 3.5mm connector fixed offset short circuit termination used to establish reference planes and calibrate vector network analyzers. It has a phase accuracy of ±2.0°, a reflection coefficient of 0.98, and an offset length of 0.1970 inches, with a frequency range of DC to 26.5 GHz.

Suppliers

Company
Product
Description
Supplier Links
VNA Calibration Standard - 8046F6 - Maury Microwave
Ontario, CA, United States
VNA Calibration Standard
8046F6
VNA Calibration Standard 8046F6
Fixed flush and fixed offset short circuit terminations (shorts) are used to establish reference planes in transmission systems and as key elements in the calibration of vector network analyzers (VNAs). Offset shorts can be used for banded calibrations of VNA. Those with the longest offset are often used to evaluate the calibration effectiveness of a VNA by measuring the effective source match after calibration.

Fixed flush and fixed offset short circuit terminations (shorts) are used to establish reference planes in transmission systems and as key elements in the calibration of vector network analyzers (VNAs). Offset shorts can be used for banded calibrations of VNA. Those with the longest offset are often used to evaluate the calibration effectiveness of a VNA by measuring the effective source match after calibration.

Supplier's Site Datasheet

Technical Specifications

  Maury Microwave
Product Category Calibration Instruments
Product Number 8046F6
Product Name VNA Calibration Standard
Calibration Signal Signal / Waveform Generator Output
Unlock Full Specs
to access all available technical data

Similar Products

VNA Calibration Standard - 361N2 - Maury Microwave
Specs
Calibration Signal Signal / Waveform Generator Output
Frequency Range 2.60E9 to 5.00E10 Hz
View Details
VNA Calibration Standard - 7931A2 - Maury Microwave
Specs
Calibration Signal Signal / Waveform Generator Output
Frequency Range 2.60E9 to 5.00E10 Hz
Electrical Properties Resistance/ Impedance
View Details
Automated Tuner - NT-5G-67G-2C-C - Maury Microwave
Specs
Calibration Signal Signal / Waveform Generator Output
Frequency Range 6.70E10 Hz
Electrical Properties Resistance/ Impedance
View Details
VNA Calibration Standard - 8773A4 - Maury Microwave
Specs
Calibration Signal Signal / Waveform Generator Output
Frequency Range 4.00E10 Hz
View Details