Maury Microwave VNA Calibration Standard 7948B2

Description
Shielded, coaxial opens are used in the calibration of vector network analyzers to provide a nominal 180° phase offset from a compatible reference short over a wide range of frequencies. At these frequencies, open circuit terminations are inherently imperfect. Shielding the open essentially eliminates radiation loss, but creates a residual frequency-sensitive capacitance. An accurate knowledge of the open’s effective capacitance is essential to an accurate calibration of the analyzer. Maury opens are characterized for effective capacitance versus frequency by means of a fourth order polynomial curve fit, and the nominal capacitance coefficients are provided with each unit.
Request a Quote
Description
Shielded, coaxial opens are used in the calibration of vector network analyzers to provide a nominal 180° phase offset from a compatible reference short over a wide range of frequencies. At these frequencies, open circuit terminations are inherently imperfect. Shielding the open essentially eliminates radiation loss, but creates a residual frequency-sensitive capacitance. An accurate knowledge of the open’s effective capacitance is essential to an accurate calibration of the analyzer. Maury opens are characterized for effective capacitance versus frequency by means of a fourth order polynomial curve fit, and the nominal capacitance coefficients are provided with each unit.
Request a Quote
Datasheet
Datasheet Summary
Powered by GS/AI

The 7948B2 is a male 2.4mm connector shielded coaxial open circuit calibration standard for vector network analyzers, designed to provide a nominal 180° phase offset with a phase accuracy of ±2.0° from DC to 50.0 GHz. It features a captivated center conductor contact flush with the outer conductor mating plane to eliminate dependence on test port connector tolerances and improve repeatability. Effective capacitance versus frequency is characterized by a fourth-order polynomial curve fit, with coefficients provided for each unit.

Datasheet Summary
Powered by GS/AI

The 7948B2 is a male 2.4mm connector shielded coaxial open circuit calibration standard for vector network analyzers, designed to provide a nominal 180° phase offset with a phase accuracy of ±2.0° from DC to 50.0 GHz. It features a captivated center conductor contact flush with the outer conductor mating plane to eliminate dependence on test port connector tolerances and improve repeatability. Effective capacitance versus frequency is characterized by a fourth-order polynomial curve fit, with coefficients provided for each unit.

Suppliers

Company
Product
Description
Supplier Links
VNA Calibration Standard - 7948B2 - Maury Microwave
Ontario, CA, United States
VNA Calibration Standard
7948B2
VNA Calibration Standard 7948B2
Shielded, coaxial opens are used in the calibration of vector network analyzers to provide a nominal 180° phase offset from a compatible reference short over a wide range of frequencies. At these frequencies, open circuit terminations are inherently imperfect. Shielding the open essentially eliminates radiation loss, but creates a residual frequency-sensitive capacitance. An accurate knowledge of the open’s effective capacitance is essential to an accurate calibration of the analyzer. Maury opens are characterized for effective capacitance versus frequency by means of a fourth order polynomial curve fit, and the nominal capacitance coefficients are provided with each unit.

Shielded, coaxial opens are used in the calibration of vector network analyzers to provide a nominal 180° phase offset from a compatible reference short over a wide range of frequencies. At these frequencies, open circuit terminations are inherently imperfect. Shielding the open essentially eliminates radiation loss, but creates a residual frequency-sensitive capacitance. An accurate knowledge of the open’s effective capacitance is essential to an accurate calibration of the analyzer. Maury opens are characterized for effective capacitance versus frequency by means of a fourth order polynomial curve fit, and the nominal capacitance coefficients are provided with each unit.

Supplier's Site Datasheet

Technical Specifications

  Maury Microwave
Product Category Calibration Instruments
Product Number 7948B2
Product Name VNA Calibration Standard
Calibration Signal Signal / Waveform Generator Output
Unlock Full Specs
to access all available technical data

Similar Products

VNA Calibration Kit - 8850CK51 - Maury Microwave
Specs
Calibration Signal Signal / Waveform Generator Output
Frequency Range 2.60E9 to 5.00E10 Hz
View Details
VNA Calibration Standard - 361P2 - Maury Microwave
Specs
Calibration Signal Signal / Waveform Generator Output
Frequency Range 2.60E9 to 5.00E10 Hz
View Details
VNA Calibration Standard - F344B - Maury Microwave
Specs
Calibration Signal Signal / Waveform Generator Output
Frequency Range 2.60E9 to 5.00E10 Hz
View Details
VNA Calibration Standard - 8772F4 - Maury Microwave
Specs
Calibration Signal Signal / Waveform Generator Output
Frequency Range 2.60E9 to 5.00E10 Hz
View Details