IMI Life Science LN-Series LN001NIP010

Description
Precision high voltage modules delivering exceptionally low levels of noise and drift, designed for easy integration into systems requiring multiple high voltages. Applications include mass spectrometry and electron gun operations. Exceptionally low levels of low frequency (LF) noise and drift High stability, low ripple, low microphon Fast recovery from load transients Analogue or digital control options Differential analogue input Short circuit and flashover proof Positive, negative and reversible versions <10ppm/°C temperature co-efficient
Request a Quote
Description
Precision high voltage modules delivering exceptionally low levels of noise and drift, designed for easy integration into systems requiring multiple high voltages. Applications include mass spectrometry and electron gun operations. Exceptionally low levels of low frequency (LF) noise and drift High stability, low ripple, low microphon Fast recovery from load transients Analogue or digital control options Differential analogue input Short circuit and flashover proof Positive, negative and reversible versions <10ppm/°C temperature co-efficient
Request a Quote
Datasheet
Datasheet Summary
Powered by GS/AI

Precision high voltage module designed for applications requiring low noise and drift, such as mass spectrometry and electron gun systems. It provides a negative 1 kV output with 5 mA current capability, featuring less than 2 mVp-p low frequency noise and ripple at full load, and a temperature coefficient of less than 10 ppm/°C. The module measures 147 x 98 x 47 mm and weighs 1.0 kg. It includes a 1 m low noise screened cable for the high voltage output and supports analogue control via differential input. The unit is short circuit proof and operates within a temperature range of +10°C to +50°C.

Datasheet Summary
Powered by GS/AI

Precision high voltage module designed for applications requiring low noise and drift, such as mass spectrometry and electron gun systems. It provides a negative 1 kV output with 5 mA current capability, featuring less than 2 mVp-p low frequency noise and ripple at full load, and a temperature coefficient of less than 10 ppm/°C. The module measures 147 x 98 x 47 mm and weighs 1.0 kg. It includes a 1 m low noise screened cable for the high voltage output and supports analogue control via differential input. The unit is short circuit proof and operates within a temperature range of +10°C to +50°C.

Suppliers

Company
Product
Description
Supplier Links
LN-Series - LN001NIP010 - IMI Life Science
Farmington, CT, United States
LN-Series
LN001NIP010
LN-Series LN001NIP010
Precision high voltage modules delivering exceptionally low levels of noise and drift, designed for easy integration into systems requiring multiple high voltages. Applications include mass spectrometry and electron gun operations. Exceptionally low levels of low frequency (LF) noise and drift High stability, low ripple, low microphon Fast recovery from load transients Analogue or digital control options Differential analogue input Short circuit and flashover proof Positive, negative and reversible versions <10ppm/°C temperature co-efficient

Precision high voltage modules delivering exceptionally low levels of noise and drift, designed for easy integration into systems requiring multiple high voltages. Applications include mass spectrometry and electron gun operations.

  • Exceptionally low levels of low frequency (LF) noise and drift
  • High stability, low ripple, low microphon
  • Fast recovery from load transients
  • Analogue or digital control options
  • Differential analogue input
  • Short circuit and flashover proof
  • Positive, negative and reversible versions
  • <10ppm/°C temperature co-efficient
Supplier's Site Datasheet

Technical Specifications

  IMI Life Science
Product Category Power Supplies
Product Number LN001NIP010
Product Name LN-Series
Applications Analytical
Unlock Full Specs
to access all available technical data

Similar Products

3590-Series - 3590-2C20 - IMI Life Science
IMI Life Science
Specs
Applications Analytical
DC Output Voltage -10000.0 volts
DC Output Current 5.00E-4 to 0.0020 amps
View Details
LN-Series - LN010RIP010 - IMI Life Science
IMI Life Science
Specs
Applications Analytical
DC Output Voltage 10000.0 volts
DC Output Current 2.50E-4 to 0.0050 amps
View Details
LN-Series - LN001RIP010 - IMI Life Science
IMI Life Science
Specs
Applications Analytical
DC Output Voltage 1000.0 volts
DC Output Current 2.50E-4 to 0.0050 amps
View Details
3590-Series - 3590-2A20 - IMI Life Science
IMI Life Science
Specs
Applications Analytical
DC Output Voltage -5000.0 volts
DC Output Current 5.00E-4 to 0.0020 amps
View Details