The Model 200M is a complete instrument for the measurement of atmospheric dew or frost point, ambient temperature, percent relative humidity and other psychrometric variables. It employs the very reliable optical chilled mirror sensing technique which provides a primary measurement of dew point, and is traceable to NIST. The Model 200M is ideally suited for installations requiring continuous, automatic, and unattended measurement of humidity over a very wide range.
Automatic Balance Control (ABC) cycle corrects the light reducing effects of mirror contaminants and allows for continuous monitoring and virtually maintenance-free operation. This is the first and only chilled mirror technology that truly reduces the need for cleaning by the incorporation of self-diagnostics, which indicates to the user, locally via an LED light source and remotely via logic level TTL signal, when and if maintenance is required.
Primary measurement technique
High accuracy and reliability
Certificate of Traceability to NIST provided
Sensing scheme discriminates between dew and contamination
Reduces maintenance requirements
No drift, no hysteresis
Fast response
No sensor calibration required
Self-diagnostics and continuous unattended operation. No balancing or other adjustments required
Chilled mirror sensor selection required
The Model 200M is a complete instrument for the measurement of atmospheric dew or frost point, ambient temperature, percent relative humidity and other psychrometric variables. It employs the very reliable optical chilled mirror sensing technique which provides a primary measurement of dew point, and is traceable to NIST. The Model 200M is ideally suited for installations requiring continuous, automatic, and unattended measurement of humidity over a very wide range.
Automatic Balance Control (ABC) cycle corrects the light reducing effects of mirror contaminants and allows for continuous monitoring and virtually maintenance-free operation. This is the first and only chilled mirror technology that truly reduces the need for cleaning by the incorporation of self-diagnostics, which indicates to the user, locally via an LED light source and remotely via logic level TTL signal, when and if maintenance is required.
- Primary measurement technique
- High accuracy and reliability
- Certificate of Traceability to NIST provided
- Sensing scheme discriminates between dew and contamination
- Reduces maintenance requirements
- No drift, no hysteresis
- Fast response
- No sensor calibration required
- Self-diagnostics and continuous unattended operation. No balancing or other adjustments required
- Chilled mirror sensor selection required