TSI Incorporated PLIF System Concentration and Velocity Measurement MODULE4G-PLIF

Description
The TSI PowerView™ PIV system-based Global Liquid Concentration Analyzer (GLCA) and Global Liquid Mixing Analyzer (GLMA) are designed to meet the research needs of anyone needing a fully integrated, turn-key system that provides global species measurements in mixing, materials processing, heat/mass transfer, and other liquid based environments. Both systems use planar laser-induced fluorescence (PLIF) to provide global concentration measurement of the species of interest in the laser sheet region. Both systems are composed of three integrated sub-systems: the Illumination System, the Imaging System, and the Display and Analysis System. The only difference is that the GLMA system provides simultaneous concentration AND velocity fields, to fully characterize micro-fluidic mixers, reactors, and numerous other processes. GLMA and GLCA systems are composed of three sub-systems: The Illumination Sub-system includes a Nd:YAG laser, lenses, and beam delivery optics to get the light sheet where you need it. The Imaging Sub-system features one (GLCA) or two (GLMA) TSI PowerView cameras with the right resolution, sensitivity, and speed required for your application. The laser and camera are controlled by a TSI LaserPulse Synchronizer, which is fully integrated into the revolutionary INSIGHT 4G Global Imaging software platform, which not only provides data analysis and display capabilities, but also directly controls the hardware components for simple system operation. Applications Mixing studies Temperature Measurements Concentration Measurements Features & Benefits Provides global measurements of scalar quantities such as concentration and temperature Advanced analysis algorithms to account for camera noise, background signals, spatial variations in laser sheet intensity, temporal variations in laser pulse energy User-programmable image analysis schemes for maximum experimental flexibility Full range of camera support, including all TSI intensified and un-intensified cameras Seamless integration with TSI PIV systems for simultaneous global velocity measurements
Datasheet

Suppliers

Company
Product
Description
Supplier Links
PLIF System Concentration and Velocity Measurement - MODULE4G-PLIF - TSI Incorporated
Shoreview, MN, United States
PLIF System Concentration and Velocity Measurement
MODULE4G-PLIF
PLIF System Concentration and Velocity Measurement MODULE4G-PLIF
The TSI PowerView™ PIV system-based Global Liquid Concentration Analyzer (GLCA) and Global Liquid Mixing Analyzer (GLMA) are designed to meet the research needs of anyone needing a fully integrated, turn-key system that provides global species measurements in mixing, materials processing, heat/mass transfer, and other liquid based environments. Both systems use planar laser-induced fluorescence (PLIF) to provide global concentration measurement of the species of interest in the laser sheet region. Both systems are composed of three integrated sub-systems: the Illumination System, the Imaging System, and the Display and Analysis System. The only difference is that the GLMA system provides simultaneous concentration AND velocity fields, to fully characterize micro-fluidic mixers, reactors, and numerous other processes. GLMA and GLCA systems are composed of three sub-systems: The Illumination Sub-system includes a Nd:YAG laser, lenses, and beam delivery optics to get the light sheet where you need it. The Imaging Sub-system features one (GLCA) or two (GLMA) TSI PowerView cameras with the right resolution, sensitivity, and speed required for your application. The laser and camera are controlled by a TSI LaserPulse Synchronizer, which is fully integrated into the revolutionary INSIGHT 4G Global Imaging software platform, which not only provides data analysis and display capabilities, but also directly controls the hardware components for simple system operation. Applications Mixing studies Temperature Measurements Concentration Measurements Features & Benefits Provides global measurements of scalar quantities such as concentration and temperature Advanced analysis algorithms to account for camera noise, background signals, spatial variations in laser sheet intensity, temporal variations in laser pulse energy User-programmable image analysis schemes for maximum experimental flexibility Full range of camera support, including all TSI intensified and un-intensified cameras Seamless integration with TSI PIV systems for simultaneous global velocity measurements

The TSI PowerView™ PIV system-based Global Liquid Concentration Analyzer (GLCA) and Global Liquid Mixing Analyzer (GLMA) are designed to meet the research needs of anyone needing a fully integrated, turn-key system that provides global species measurements in mixing, materials processing, heat/mass transfer, and other liquid based environments. Both systems use planar laser-induced fluorescence (PLIF) to provide global concentration measurement of the species of interest in the laser sheet region.

Both systems are composed of three integrated sub-systems: the Illumination System, the Imaging System, and the Display and Analysis System. The only difference is that the GLMA system provides simultaneous concentration AND velocity fields, to fully characterize micro-fluidic mixers, reactors, and numerous other processes. GLMA and GLCA systems are composed of three sub-systems: The Illumination Sub-system includes a Nd:YAG laser, lenses, and beam delivery optics to get the light sheet where you need it. The Imaging Sub-system features one (GLCA) or two (GLMA) TSI PowerView cameras with the right resolution, sensitivity, and speed required for your application.

The laser and camera are controlled by a TSI LaserPulse Synchronizer, which is fully integrated into the revolutionary INSIGHT 4G Global Imaging software platform, which not only provides data analysis and display capabilities, but also directly controls the hardware components for simple system operation.

Applications

  • Mixing studies
  • Temperature Measurements
  • Concentration Measurements

Features & Benefits

  • Provides global measurements of scalar quantities such as concentration and temperature
  • Advanced analysis algorithms to account for camera noise, background signals, spatial variations in laser sheet intensity, temporal variations in laser pulse energy
  • User-programmable image analysis schemes for maximum experimental flexibility
  • Full range of camera support, including all TSI intensified and un-intensified cameras
  • Seamless integration with TSI PIV systems for simultaneous global velocity measurements
Supplier's Site Datasheet

Technical Specifications

  TSI Incorporated
Product Category Linear Velocity Sensors
Product Number MODULE4G-PLIF
Product Name PLIF System Concentration and Velocity Measurement
Unlock Full Specs
to access all available technical data

Similar Products

Laser Surface Velocimeter - LSV-6000 - Polytec, Inc.
Specs
Technology Optical
Output / Interface Voltage; Current (optional feature); Serial; Ethernet (optional feature); TTL
Device Category Instrument / Meter
View Details
Series 100 -  Linear Velocity Transducers - Model 0127-0001 - Trans-Tek, Inc.
Specs
Technology Magnetic Induction
Output / Interface Voltage
Device Category Sensor / Transducer
View Details
Universal Transmitter - 682A06 - PCB Piezotronics, Inc.
PCB Piezotronics, Inc.
Specs
Device Category Sensor / Transducer
Operating Temperature -4 to 140 F (-20 to 60 C)
View Details
Sensors -  - MFP Automation Engineering
MFP Automation Engineering
View Details