Bio-Rad Laboratories, Inc. Mini 2-D Tube Gel Ejector 165-2967

Description
Pkg of 1, tube gel ejector for tube gel IEF The Mini-PROTEAN 2-D electrophoresis cell performs both tube gel IEF and vertical electrophoresis applications. First-dimension IEF typically takes 3.5 hours, and second-dimension SDS-PAGE takes 45 minutes. The entire 2-D procedure, including silver staining, can be completed in a single cell and in less than a day. Cast up to 16 tube gels in the glass tubes, then attach the tube gels to molded sample reservoirs for the IEF run Following first-dimension IEF, remove the gels using the mini 2-D tube gel ejector and slide them between the plates of the slab gel for the second-dimension run Cell is IEC 1010 safety certified The Mini-PROTEAN tube cell module transforms the following units into a mini 2-D electrophoresis cell: Mini Trans-Blot cell Mini-PROTEAN II slab cell Mini-PROTEAN 3 cell The Mini-PROTEAN tube cell module may be used with the tank and lid of the Mini Trans-Blot cells of older Mini-PROTEAN II or Mini-PROTEAN 3 systems; the tube cell module is not compatible with the Mini-PROTEAN Tetra system. The Mini-PROTEAN tube cell (for casting tube gels and performing first-dimension IEF) and the tube cell module (for casting tube gels) are also available separately. The PowerPac HV power supply is recommended for use with the Mini-PROTEAN 2-D electrophoresis cell.
Description
Pkg of 1, tube gel ejector for tube gel IEF The Mini-PROTEAN 2-D electrophoresis cell performs both tube gel IEF and vertical electrophoresis applications. First-dimension IEF typically takes 3.5 hours, and second-dimension SDS-PAGE takes 45 minutes. The entire 2-D procedure, including silver staining, can be completed in a single cell and in less than a day. Cast up to 16 tube gels in the glass tubes, then attach the tube gels to molded sample reservoirs for the IEF run Following first-dimension IEF, remove the gels using the mini 2-D tube gel ejector and slide them between the plates of the slab gel for the second-dimension run Cell is IEC 1010 safety certified The Mini-PROTEAN tube cell module transforms the following units into a mini 2-D electrophoresis cell: Mini Trans-Blot cell Mini-PROTEAN II slab cell Mini-PROTEAN 3 cell The Mini-PROTEAN tube cell module may be used with the tank and lid of the Mini Trans-Blot cells of older Mini-PROTEAN II or Mini-PROTEAN 3 systems; the tube cell module is not compatible with the Mini-PROTEAN Tetra system. The Mini-PROTEAN tube cell (for casting tube gels and performing first-dimension IEF) and the tube cell module (for casting tube gels) are also available separately. The PowerPac HV power supply is recommended for use with the Mini-PROTEAN 2-D electrophoresis cell.

Suppliers

Company
Product
Description
Supplier Links
Mini 2-D Tube Gel Ejector - 165-2967 - Bio-Rad Laboratories, Inc.
Hercules, CA, USA
Mini 2-D Tube Gel Ejector
165-2967
Mini 2-D Tube Gel Ejector 165-2967
Pkg of 1, tube gel ejector for tube gel IEF The Mini-PROTEAN 2-D electrophoresis cell performs both tube gel IEF and vertical electrophoresis applications. First-dimension IEF typically takes 3.5 hours, and second-dimension SDS-PAGE takes 45 minutes. The entire 2-D procedure, including silver staining, can be completed in a single cell and in less than a day. Cast up to 16 tube gels in the glass tubes, then attach the tube gels to molded sample reservoirs for the IEF run Following first-dimension IEF, remove the gels using the mini 2-D tube gel ejector and slide them between the plates of the slab gel for the second-dimension run Cell is IEC 1010 safety certified The Mini-PROTEAN tube cell module transforms the following units into a mini 2-D electrophoresis cell: Mini Trans-Blot cell Mini-PROTEAN II slab cell Mini-PROTEAN 3 cell The Mini-PROTEAN tube cell module may be used with the tank and lid of the Mini Trans-Blot cells of older Mini-PROTEAN II or Mini-PROTEAN 3 systems; the tube cell module is not compatible with the Mini-PROTEAN Tetra system. The Mini-PROTEAN tube cell (for casting tube gels and performing first-dimension IEF) and the tube cell module (for casting tube gels) are also available separately. The PowerPac HV power supply is recommended for use with the Mini-PROTEAN 2-D electrophoresis cell.

Pkg of 1, tube gel ejector for tube gel IEF

The Mini-PROTEAN 2-D electrophoresis cell performs both tube gel IEF and vertical electrophoresis applications. First-dimension IEF typically takes 3.5 hours, and second-dimension SDS-PAGE takes 45 minutes. The entire 2-D procedure, including silver staining, can be completed in a single cell and in less than a day.

  • Cast up to 16 tube gels in the glass tubes, then attach the tube gels to molded sample reservoirs for the IEF run
  • Following first-dimension IEF, remove the gels using the mini 2-D tube gel ejector and slide them between the plates of the slab gel for the second-dimension run
  • Cell is IEC 1010 safety certified

The Mini-PROTEAN tube cell module transforms the following units into a mini 2-D electrophoresis cell:

  • Mini Trans-Blot cell
  • Mini-PROTEAN II slab cell
  • Mini-PROTEAN 3 cell

The Mini-PROTEAN tube cell module may be used with the tank and lid of the Mini Trans-Blot cells of older Mini-PROTEAN II or Mini-PROTEAN 3 systems; the tube cell module is not compatible with the Mini-PROTEAN Tetra system. The Mini-PROTEAN tube cell (for casting tube gels and performing first-dimension IEF) and the tube cell module (for casting tube gels) are also available separately.

The PowerPac HV power supply is recommended for use with the Mini-PROTEAN 2-D electrophoresis cell.